Datasheet
VI-2015, www.findernet.com
2
K
13 SERIES
Electronic step/monostable relays 16A
13
SERIES
13.01 - Electronic step/monostable relay
Rail mount - 1 Pole
13.61 - Multifunction step/monostable relay
with reset command - Rail mount 1 Pole
• Selectable Step or Monostable operation (13.01)
• Multifunction (Step, Timing step, Monostable,
Light ON) (13.61)
• Reset feature, for centralized off command
(13.61)
• Set feature, for centralized on command
(13.61.0.024)
• Control input can be continuously applied
• Longer mechanical and electrical life, and much
quieter than electromechanical step relays
• 12…24VAC/DC and 110…240VAC supply
versions (13.61)
• Suitable for SELV applications and available
also for supply 12 and 24VAC/DC (13.01)
• “Zero-crossing” load switching (13.61)
• 35mm rail (EN60715) mount
• Cadmium free contact material
13.01/61
Screw terminals
13.01 13.61.0.024.0000 13.61.8.230.0000
• 1 CO (SPDT)
• Step or monostable relay
• 35mm rail (EN60715) mount
• 35mm wide
• 1 CO (SPDT)
• Reset feature, for centralized
off command
• Set feature, for centralized on
command
• Multifunction:
- step relay
- timing step relay
- monostable relay
- light on
• 35mm rail (EN60715) mount
• 17.5mm wide
• 1 NO (SPST-NO)
• Reset feature, for centralized
off command
• Multifunction:
- step relay
- timing step relay
- monostable relay
- light on
• 35mm rail (EN60715) mount
• 17.5mm wide
For outline drawing see page 10
Contact specification
Contact configuration 1 CO (SPDT) 1 CO 1 NO
Rated current/Maximum peak current A 16/30 (120A - 5ms) 16/30 (120A - 5ms) 16/30 (120A - 5ms)
Rated voltage/
Maximum switching voltage VAC 250/400 250/400 250/400
Rated load AC1 VA 4000 4000 4000
Rated load AC15 (230VAC) VA 750 750 750
Nominal lamp rating:
230V incandescent/halogen W 2000 2000 3000
fluorescent tubes with
electronic ballast W 1000 1000 1500
fluorescent tubes with
electromechanical ballast W 750 750 1000
CFL W 400 400 600
230V LED W 400 400 600
LV halogen or LED with
electronic ballast W 400 400 600
LV halogen or LED with
electromechanical ballast W 800 800 1500
Minimum switching load mW (V/mA) 1000 (10/10) 1000 (10/10) 1000 (10/10)
Standard contact material AgSnO
2
AgSnO
2
AgSnO
2
Supply specification
Nominal voltage (U
N
) VAC (50/60Hz) 110…125 230…240 — 110…240
VDC/AC (50/60Hz) 12 24 12…24 —
Rated power AC/DC V A (50/60Hz)/W 2.5/2.5 1/0.5 3.2/1
Operating range VAC (50Hz) 90…130 184…253 — 90…264
VDC/AC (50Hz) 10.8…13.2 20.6…33.6 10.2…26.4 —
Technical data
Electrical life at rated load in AC1 cycles 100·10
3
100·10
3
100·10
3
Maximum impulse duration continuous continuous continuous
Dielectric strength between: open contacts VAC 1000 1000 1000
supply - contacts VAC 4000 2000 2000
Ambient temperature range °C –10…+60 –10…+60 –10…+60
Protection category IP 20 IP 20 IP 20
Approvals (according to type)