Data Sheet

5
I-2017, www.findernet.com
I
15
SERIES
15 SERIES
Dimmers
Ordering information
Example: type 15.91, Dimmer, 230VAC.
1 5 . 9 1 . 8 . 2 3 0 . 0 0 0 0
Series
Type
1 = Master / slave, 35mm rail (EN60715)
mount, 17.5mm wide
5 = Panel or wall box mount
8 = 35mm rail (EN60715) mount,
17.5mm wide, for energy saving lamps
9 = Wall box mount, for LED lamps
No. of poles
0 = 0-10V output (only for 15.10)
1 = 1 output
Supply voltage
230 = 230V
230 = 110…230V
(only for 15.10)
Supply version
8 = AC
0 = Standard
4 = Only for 15.51 linear dimming
AC input frequency
0 = 50Hz (15.51)
50/60Hz (15.11/81/91)
1 = 50/60Hz (15.10)
6 = 60Hz (15.51)
Output power
0 = 100W (15.91)
4 = 400W (15.51,15.11)
5 = 500W (15.81)
Codes
15.10.8.230.0010 master dimmer, 50/60Hz
15.11.8.230.0400 slave dimmer, 50/60Hz
15.51.8.230.0400 step dimming, 50Hz
15.51.8.230.0404 linear dimming, 50Hz
15.51.8.230.0460 step dimming, 60Hz
15.81.8.230.0500 linear dimming, 50/60Hz
15.91.8.230.0000 linear dimming, 50/60Hz
Technical data
EMC specifications
Type of test Reference standard 15.51/15.91 15.10/11/81
Electrostatic discharge
contact discharge EN61000-4-2 4kV
air discharge EN61000-4-2 8kV
Radiated electromagnetic field (80…1000MHz) EN61000-4-3 3V/m 10V/m
Fast transients (burst)
(5-50ns, 5 and 100kHz)
on supply terminals EN61000-4-4 4kV
on pushbutton connection EN61000-4-4 4kV
Voltage pulses on supply terminals
(surge 1.2/50µs) differential mode EN61000-4-5 2kV
Radiofrequency common mode voltage
(0.15…80MHz)
on supply terminals EN61000-4-6 3V
on pushbutton connection EN61000-4-6 3V
Voltage dips 70%U
N
, 40%U
N
EN61000-4-11 10 cycles
Short interruptions EN61000-4-11 10 cycles
Radiofrequency conducted emissions 0.15…30MHz EN 55014 class B
Radiated emissions 30…1000MHz EN 55014 class B
Terminals solid cable stranded cable
Max. wire size mm
2
1x6 / 2x4 1x4 / 2x2.5
AWG 1x10 / 2x12 1x12 / 2x14
Screw torque Nm 0.8
Wire strip length mm 9
Other data 15.10 15.11 15.51 15.81 15.91
Power lost to the environment without load W 0.5 0.5 0.7 0.5 0.4
with rated load W 1.7 2.5 2.2 2.6 1.2
Max cable length for push-button connection m 100 100 100 100 100
Max cable length for Master and Slaves connection m 100 (keep separate from power cables)