Datasheet

Box or panel mount
Maximum lamp load 400 W
Two operating modes
Two different types for linear
and step dimming
Trailing edge dimming
method
For mounting within
residential switch boxes
Maximum lamp load 100 W
Two operating modes
Leading edge dimming
method
Compatible with LED
dimmable lamps
17.5 mm modular
Maximum lamp load 500 W
Multi-function
Leading and trailing edge
dimming methods (depending
on the function)
Compatible with energy
saving dimmable lamps
1
Features
Electronic step relay and dimmer for control of
lighting levels
Suitable for incandescent and halogen lighting
loads (with or without transformer or electronic
supply)
Version compatible with energy saving (CFL or
LED) dimmable lamps and with all types of
electromagnetic transformers, even in no-load
condition (15.81)
Version compatible with 230 V LED dimmable
lamps (15.91)
Use with 3 or 4 wire connection
“Soft” On and Off transitions
Two selectable operating modes:
with or without previous light level memory
Step (15.51 only) or linear dimming
Thermal protection against overload
Thermo-fuse for extreme protection (15.81)
230 V AC supply, 50 Hz (15.91), 50 or 60 Hz
(15.51), 50/60 Hz with automatic recognition
of frequency (15.81)
15.91 15.51 15.81
230 230 230
100 400 500
310 3
100 400 500
(1)
300
(2)
500
(3)
500
(3)
400
(4)
500
(1)
100
(5)
50 100
(5)
50
(6)
100
(1)
230
(6)
230
230
(7)
230
(8)
230
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
0.4 0.7 0.5
Leading edge Trailing edge Trailing edge (pos. )
Leading edge (pos. )
and ( )
–10…+50
(9)
–10…+50
(9)
–10…+50
(10)
IP 20 IP 20 IP 20
Output data
Rated voltage V AC
Power max. W
Power min. W
Nominal lamp rating: 230 V incandescent or halogen W
toroidal electromagnetic transformers for LV halogen W
E-core electromagnetic transformers for LV halogen W
electronic transformers (ballasts) for LV halogen W
dimmable compact fluorescent (CFL) W
dimmable 230 V LED W
dimmable electronic transformers for LV LED W
Supply specifications
Nominal voltage (U
N
) V AC (50/60 Hz)
Operating range
Stand-by power consumption W
Dimming operating mode
Technical data
Ambient temperature range °C
Protection category
Approvals (according to type)
Note
(1)
Select “incandescent lamp” ( ) position on the front selector.
(2)
One transformer only. Power-up only with the lamp load connected.
(3)
Select “transformer” ( ) position on the front selector. Preferably, no more than 2 transformers.
(4)
One transformer only.
(5)
Select “CFL” ( ) position on the front selector, and set the appropriate minimum dimming value (dependent on lamp type).
(6)
Only if electronic transformers are compatible with leading edge method.
(7)
Only 50 Hz version available.
(8)
Specific 60 Hz version available (see ordering information).
(9)
It is not recommended to mount more than one dimmer in the same wall box, unless an adequate ventilation is provided or the lamp load is
less than 100 W (15.51) or 50 W (15.91).
(10)
With lamp load > 300 W, adequate ventilation must be provided - a gap of 5 mm on both side of the dimmer is suggested.
Not compatible with illuminated push-buttons.
15 Series - Electronic step relay and dimmer
Screw terminal
For outline drawing see page 6
II-2013, www.findernet.com
SERIE