C.61 SLIDER CHRONOTHERMOSTAT www.findernet.
INDEX TECHNICAL DATA ...................................................................................................page 34 DIMENSIONS............................................................................................................page 34 INSTALLATION AND CONNECTIONS.............................................................page 36 BATTERY......................................................................................................................page 38 START UP....................
TECHNICAL DATA Power supply: 2 Alkaline batteries 1.5 V AAA Winter temperature range: (+6…+24)°C Summer temperature range: (+18…+30)°C Manual temperature range: (+5…+37)°C Frost protection temperature range: (+2…+8)°C ON/OFF hysteresis: (0.1…0.9)°C Internal sensor accuracy: +/– 0.
3
INSTALLATION AND CONNECTIONS SAFETY REQUIREMENTS Before connecting to this programmable thermostat, make sure that the load (heater, pump, etc.) is not connected to the supply and that the load is within the ratings shown inside the thermostat. POSITIONING Install the programmable thermostat away from sources of heat (heaters, direct sunlight, kitchens) and from doors/windows, and at a height of about 1.5 m above the floor. CLEANING For cleaning - use only a damp cloth.
fig.1 1 2 fig.
BATTERY To insert or change the batteries, see the picture below. ATTENTION - Incorrect placement of the batteries (reverse polarity) may damage the thermostat. - To increase battery life, always keep the slider cover of the thermostat closed. - If the battery charge falls below the minimum level, the thermostat is placed in the OFF state and the output relay releases. - If the thermostat remains unused for long periods it is advisable to remove the batteries.
START UP Insert the batteries, the display will show the software version.
KEYS WITH THERMOSTAT OFF Switch on the thermostat S E T Pressed for 3 seconds, it is possible to access at the advanced menu WITH THERMOSTAT ON Switch off the thermostat Activates the MANUAL mode. Pressed for 3 seconds it is possible to program the TIMED MANUAL mode (HOLIDAY function) Allows the time and date to be set Activates or de-activates the LOCK mode day (Visible only if activated in the advanced menu).
SYMBOLS The display is back-lit. Each time that the display is touched, a key pressed, the protective door opened or the sliders moved, the display will activate the backlight for about 5 seconds.
TIME / DATE SETTING . To set time and date press the button Data to be set appears in the following order: HOURS/MINUTES/DAY/MONTH/YEAR Figures that are flashing, can be changed using the keys Confirm with OK and advance to the next parameter. . To go back or exit from the menu, press EXAMPLE Press . The hour flashes. Enter the correct time through keys . . Pressing OK confirms the hour setting and it is then possible to set the MINUTES, using the same method.
Press OK confirm the day and proceed to set the MONTH Press OK to confirm the month and proceed to set the YEAR Press OK to confirm and exit the Time/Date setting menu. The display will then show the main screen.
MANUAL MODE From the main screen press the manual temperature previously set will flash. To change it, use to increase or To confirm and exit, press to decrease the value. NOTE If you do not touch the display for 3 seconds, the screen will revert to the measured (current) temperature. DISPLAY LOCK This function protects the thermostat from accidental touch, blocking ONLY the display keys. To activate, it is necessary to press for 2 seconds.
FULL THERMOSTAT LOCK (with PIN) This advanced feature, serves to completely block the thermostat (both the display and sliders). To enable it, you must set a 3-digit PIN that will be required every time you want to lock or unlock the thermostat.
With the keys or enter the PIN previously set in the advanced settings and press OK . 3 beeps will confirm that the lock is active and the display will show the following screen The temperatures set by the position of the sliders before the block, will be stored. The display will be locked (showing current time and temperature) and the sliders disabled. If the sliders are moved an error signal (chirp) will be produced. for 3 seconds. To unlock the thermostat, press and hold key The display will show CODE.
PROGRAMMING TEMPERATURE WITH SLIDERS On the chronothermostat there are 24 sliders, each one identifies a one hour time segment in the day. Each slider can adjust the temperature from 6°C to 24°C in the WINTER mode and from 18°C to 30°C in the SUMMER mode. 24 30 18 24 0 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 18 For every movement of the slider, the display will show for a few seconds, the hour in the day and the temperature being set, related to that slider.
DELAYED START TO TIME SEGMENTS This feature allows you to delay the start of any of the 24 time “segments” by 15, 30 or 45 minutes. This has the effect of being able to time the start of a temperature change to the nearest 15 minutes, rather than 60 minutes. To activate, it is necessary to enter into the advanced settings and enable the corresponding function. Enable the function in the advanced menu Turn off the thermostat with the button Press for 3 seconds to enter ADVANCED SETTINGS.
After a few seconds, the value will be stored and the display will return to show the main screen. NOTE When the delay program is running and the segment time is reached, the display will show the set delay i.e. +15, +30, +45.
TIMED MANUAL (HOLIDAY FUNCTION) This function serves to maintain a specified temperature for a specific time, set by the user. After the timeout, the device will return to normal conditions of use, showing the main screen again. Starting from the main display press for 2 seconds. You will see the following screen With keys set the time (hour) at which this function will terminate. Confirm with OK and proceed to set the minutes in the same way.
and the year Confirming with OK it is then possible to set the desired temperature, using . the keys Confirm the temperature with OK , and the thermostat starts the function (as indicated on the right side, by a sequence of hands which run from top to bottom). NOTE When the function is active, the display shows the measured (current) temperature and not the temperature set. If you want to see or change the set time, it is necessary press .
ADVANCED SETTINGS The advanced settings are useful for customizing the thermostat. The settings are: 1 - SUMMER-WINTER mode 2 - FROST PROTECTION Function 3 - ON/OFF HYSTERESIS Function 4 - ANTI-SEIZE PUMP Function 5 - DAYLIGHT SAVING Function 6 - FULL THERMOSTAT LOCK mode (with PIN) 7 - DAY Mode 8 - DELAYED SEGMENT START 9 - EXTERNAL TEMPERATURE SENSOR 10 - RESET To enter advanced settings start from the main screen, press the thermostat. Press S E T to turn off for 3 seconds.
2 - FROST PROTECTION function After setting the Summer or Winter mode, pressing the following screen. OK the display will show With the keys it is possible to set the desired value, between 2°C and 8°C. Press OK to confirm and proceed to the next menu. for 3 seconds or press OK repeatedly until the To exit, press the key message OFF appears on the screen. If something has been changed, 3 beeps will confirm the successful change.
The anti-seize pump function is a function that will configure the thermostat as an asymmetrical timer. By setting a value between 1 and 999 HOURS, the thermostat will close the output contact for 30 seconds, every time the set time value has elapsed. Example: By setting with keys the value 120 (120 hours = 5 days) and confirming with OK , the thermostat will close the relay contact for 30 seconds, every 5 days.
Using to set the value to 2 enables the choice of either Monday or Sunday to be day “1”. (The choice itself will be made after exiting the Advanced Settings menu). Press OK to confirm. It is now necessary to exit the Advanced setting menu and proceed to make the choice for day “1”, as follows. Press for 3 seconds (screen shows OFF). Press to turn ON. , then press OK twice to step through the HOUR and MINUTES settings. Press The display now shows the days of the week column.
Use keys to set a personal PIN selecting a number between 001 and 999. Confirm the PIN number with OK , and advancing to the next stage of the menu. Now, everytime you wish to lock the thermostat, it will be necessary press the key on the main screen. NOTE The PIN will be required each time you wish to lock or unlock the thermostat. it will be necessary to press the button on the main screen. If the PIN has been forgotten, enter the unlock code 513.
Leaving the advanced settings (Press main screen will show the day key. S E T for 3 seconds then press ), the Pressing the key day will activate the DAY function and the display shows the modes pre-programmed for each day of the week. NOTE When the function is activated “day” flashes and to the right is shown the bar of the week, with the mode set for each day (OFF, Automatic, Manual). To program every single day with one of the 3 modes, press and hold the key day for 3 seconds.
NOTE If mode OFF ( ) is set, you can reactivate the thermostat and gain access to the full main screen by pressing day . If the mode AUTO ( ) is operative, it is possible to change the temperature by the sliders. If mode MANUAL ( ) is operative, it is possible to change the temperature . by pressing and using the keys To deactivate the DAY function, press the key day , which will cease flashing. The display will then return to showing the main screen.
9 - EXTERNAL TEMPERATURE SENSOR By connecting an external sensor (01C.61 not supplied) between terminals A and B (see page 62), the thermostat can display, or be controlled by, the external temperature - according to the option selected. Using keys or select the required option. : with this setting the external sensor has no effect. : with this setting, the “Time” display alternates, every 2 seconds, between showing the current time and the external temperature.
10 - RESET This will restore all factory settings. Using or , you can enable the RESET function by selecting the ON state. Confirming with OK the thermostat will turn off completely and then turn back on showing first the version of the software and then the main screen.
REMOTE CONTROL The thermostat is equipped with two input terminals, A and B, dedicated to remote control (see page 37, figure 2). You can connect a contact to force the thermostat into the AUTO-ON condition. The display will show the message . It is possible to program two modes of operation: 1) With the LOCK mode enabled without PIN (PIN = 000), it will be possible to adjust the temperature of the thermostat with the sliders.
CALIBRATION The thermostat comes pre-calibrated from the factory. If it is required to recalibrate, precede as follows. In the main display press the key for 6 seconds. The following screen appears Using keys or to set the desired value and then press key to exit calibration. If you do not touch any key, after a few seconds, the product will recalibrate itself and present the main screen again.
www.findernet.com IB1C61002 - 01/16 FINDER S.p.A.