Contact specification
H 22 - Maximum DC1 breaking capacity - Type 22.32 / 22.34
R 22 - Coil operating range v ambient temperature
Coil specifications
Nominal Coil Operating range Rated coil
voltage code
consumption
U
N
U
min
U
max
I
N
at U
N
(AC)
VVVmA
12 0.012 9.6 13.2 165
24 0.024 19.2 26.4 83
48 0.048 38.4 52.8 42
60 0.060 48 66 33
120 0.120 88 138 16.5
(110...125)
230
184 (AC) 264 (AC)
(230...240 AC)
0.230
176 (DC) 242 (DC)
8.7
(220 DC)
AC/DC version data (type 22.34)
Nominal Coil Operating range Rated coil
voltage code
consumption
U
N
U
min
U
max
I
N
at U
N
(AC)
VVVmA
12 0.012 9.6 13.2 165
24 0.024 19.2 26.4 83
48 0.048 38.4 52.8 42
60 0.060 48 66 33
120 0.120 88 138 16.5
(110...125)
230
184 (AC) 264 (AC)
(230...240 AC)
0.230
176 (DC) 242 (DC)
8.7
(220 DC)
AC/DC version data (type 22.32)
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100·10
3
can be expected.
In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
DC breaking current (A)
DC voltage (V)
Ratings and utilization categories according to EN 61095: 2009
Type Utilization category
AC-7a AC-7b AC-7c
Rated current Rated electrical Rated current Rated electrical Rated current Rated electrical
(A) life (Cycles) (A) life (Cycles) (A) life (Cycles)
22.32….1xx0 (AgNi contacts) 25
70·10
3
(NO)
10 30·10
3
——
30·10
3
(NC)
22.32….4xx0 (AgSnO
2
contacts) 25 30·10
3
10 30·10
3
10 30·10
3
22.34….1xx0 (AgNi contacts) 25
150·10
3
(NO)
10 30·10
3
——
100·10
3
(NC)
22.34….4xx0 (AgSnO
2
contacts) 25 30·10
3
10 30·10
3
10 30·10
3
22.44….4xx0 40 100·10
3
22 150·10
3
——
22.64….4xx0 63 100·10
3
30 150·10
3
——
VI-2014, www.findernet.com
H 22 - Maximum DC1 breaking capacity - Type 22.44 / 22.64
DC breaking current (A)
DC voltage (V)
Nominal Coil Operating range Rated coil
voltage code
consumption
U
N
U
min
U
max
I
N
at U
N
(AC)
VVVmA
12 0.012 10.2 13.2 417
24 0.024 20.4 26.4 208
120 0.120 102 138 41
(110...125)
230
264 (AC)
(230...240 AC)
0.230 196
242 (DC)
21
(220 DC)
AC/DC version data (type 22.44 / 22.64)
Utilization category: AC-7a = Slightly inductive loads (cosϕ=0.8)
AC-7b = Motor loads; (cosϕ=0.45, I
making= 6xIbreaking)
AC-7c = Compensated electric discharge lamps (cosϕ=0.9, C= 10 mF/A)
type 22.64
type 22.44
22
SERIE S