Data Sheet

40- 63A modular contactor - 4 pole
NO and NC contact gap ≥3mm, double break
Continuous duty for the coil and contacts
AC/DC silent coil (with varistor protection)
Protective separation (reinforced insulation)
between coil and contacts
Mechanical indicator as standard
AgSnO
2
contacts
Compliant with EN61095:2009 and with
EN60947-4-1:2009
35mm rail (EN60715) mount
22.44…/22.64…
Screw terminal
22.44.0.xxx.4xx0 22.64.0.xxx.4xx0
* 4 NO version only
For high inrush current loads
176A
Contact material AgSnO
2
Specifically intended:
for high inrush current loads
240A
Contact material AgSnO
2
4 NO
(4310)
3 NO + 1 NC
(4710)
2 NO + 2 NC
(4610)For outline drawings see page 10
Contact specification
Contact configuration 4 NO, (or 3NO + 1NC or 2NO + 2NC) ≥3mm
Rated current/Maximum peak current A 40/176 63/240
Rated voltage VAC 400/440 400/440
Rated load AC1 / AC-7a (per pole @400V) VA 16000 24000
Rated current AC3 / AC-7b (400V) A 22 30
Rated load AC15 (per pole @230V) VA
Three-phase motor rating (400- 440VAC) kW 11 15
Rated load AC5a (per pole @250V) A 20 32
Rated current AC-7c A
Nominal lamp rating:
230V incandescent/halogen W 4000 5000
fluorescent tubes with
electronic ballast W 1500 2000
fluorescent tubes with
electromechanical ballast W 1500 2000
CFL W 1000 1500
230V LED W 1000 1500
LV halogen or LED with
electronic ballast W 1000 1500
LV halogen or LED with
electromechanical ballast W 1500 2000
Breaking capacity DC1: 30/110/220V A 40/4/1.2 63/4/1.2
Minimum switching load mW (V/mA) 1000 (17/50) 1000 (17/50)
Contact material AgSnO
2
AgSnO
2
Coil specification
Nominal voltage (U
N
) VDC/AC (50/60Hz) 12 - 24 - 110…120 (110 VDC) - 230…240 (220V DC)
Rated power AC/DC VA (50Hz)/W 5 5
Operating range DC/AC (50/60Hz) (0.85…1.1)U
N
(0.85…1.1)U
N
Holding voltage DC/AC (50/60Hz) 0.85U
N
0.85U
N
Must drop-out voltage DC/AC (50/60Hz) 0.2U
N
0.2U
N
Technical data
Mechanical life AC/DC cycles 3·10
6
3·10
6
Electrical life at rated load AC-7a cycles 100·10
3
100·10
3
Operate/release time ms 20/45 20/45
Insulation between coil
and contacts (1.2/50µs) kV 6 6
Ambient temperature range °C –15…+55 (–25...+55)* –15…+55 (–25...+55)*C
Protection category IP 20 IP 20
Approvals (according to type)
5
VII-2018, www.findernet.com
L
22
SERIES
22 SERIES
Modular contactors 25- 40- 63A