Data Sheet

Technical data
34 Series - Ultra-Slim PCB relays
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
5 7.005 3.5 7.5 130 38.4
12 7.012 8.4 18 840 14.2
24 7.024 16.8 36 3,350 7.1
48 7.048 33.6 72 12,300 3.9
60 7.060 42 90 19,700 3
DC coil data
Coil specifications
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of 60·10
3
can be expected.
In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Electromechanical relay
4
Contact specification
F 34 - Electrical life (AC) v contact current
Cycles
DC voltage (V)
DC breaking current (A)
H 34 - Maximum DC1 breaking capacity
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 34 - DC coil operating range v ambient temperature
Insulation according to EN 61810-1
Nominal voltage of supply system V AC 230/400
Rated insulation voltage V AC 250 400
Pollution degree 3 2
Insulation between coil and contact set
Type of insulation Reinforced
Overvoltage category III
Rated impulse voltage kV (1.2/50 μs) 6
Dielectric strength V AC 4,000
Insulation between open contacts
Type of disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 μs) 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 μs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 1/6
Vibration resistance (5…55)Hz: NO/NC g 10/5
Shock resistance g 20/14
Power lost to the environment without contact current W 0.2
with rated current W 0.5
Recommended distance between relays mounted on PCB mm 5
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
II-2013, www.findernet.com