Datasheet

5 mm wide
Low coil power
PCB or 93 series sockets
1
1 CO (SPDT)
6/10
250/400
1,500
300
0.185
6/0.2/0.12
500 (12/10)
AgNi
5 - 12 - 24 - 48 - 60
—/0.17
(0.7…1.5)U
N
—/0.4 U
N
—/0.05 U
N
—/10 · 10
6
60 · 10
3
5/3
6 (8 mm)
1,000
–40…+85
RT II
34.51
34 Series - Slim electromechanical PCB relays 6 A
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50 µs)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
Copper side view
Features
Ultra-slim 1 Pole - 6 A relay
Printed circuit mount
- direct or via PCB socket
35 mm rail mount
- via screw or screwless sockets
1 Pole changeover contacts or
1 Pole normally open contact
Ultra slim, 5 mm, package
Sensitive DC coil - 170 mW (Dual AC/DC coil
drive possible using 93 series sockets)
UL Listing (certain relay/socket combinations)
Cadmium Free contact materials
8/8 mm clearance/creepage distance
6 kV (1.2/50 µs) insulation, coil-contacts
28 5
153.5
0.4 1 0.4
A2 A1 12 11 14
28
5
1.9
1.3
0.8 1.3
3.75
55
11.25
F
OR
UL H
ORSEPOWER AND
P
ILOT
D
UTY RATINGS
S
EE
“General technical information” page