A
Contact specification
F 36 - Electrical life (AC) v contact current
Cycles
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
Coil specifications
DC coil data R 36 - DC coil operating range v ambient temperature
Nominal
voltage
Coil
code
Operating range Resistance Rated coil
consumption
U
N
U
min
U
max
R I at U
N
V V V
Ω
mA
3 9.003 2.2 3.9 25 120
5 9.005 3.7 6.5 70 72
6 9.006 4.5 7.8 100 60
9 9.009 6.7 11.7 225 40
12 9.012 9 15.6 400 30
18 9.018 13.5 23.4 900 20
24 9.024 18 31.2 1600 15
48 9.048 36 62.4 6400 7.5
1 - Max. permitted coil voltage.