Data Sheet

21
X-2017, www.findernet.com
39
SERIES
39 SERIES
Relay interface modules - Technical data
B
Input specifications - Solid State Relay
Input data DC, type 39.10/20/30/40/00/50/60/70
Nominal
voltage
Input
code
Operating range
Must drop-out
voltage
Rated input
current at U
N
Rated
power
(1)
60VDC, 125VDC and 220VDC for type 39.30/60 only
U
N
U
min
U
max
U
r
I
N
at U
N
V V V V mA W
6 7.006 4.8 6.6 0.6 7.5 0.2
12 7.012 9.6 13.2 1.2 20.7 0.25
24 7.024 19.2 26.4 2.4 10.5 0.25
60
(1)
7.060 38 66 6.0 6.4 0.4
125
(1)
(110…125)
7.125 88 138 12.5 4.6 0.6
220
(1)
7.220 176 242 22 3.0 0.6
Input data AC/DC, type 39.10/20/30/40/00/50/60/70
Nominal
voltage
Input
code
Operating range
Must drop-out
voltage
Rated input
current at U
N
Rated
power
(2)
24VAC/DC for type 39.30/40/60/70 only
(3)
24…240VAC/DC for type 39.30/60 only
U
N
U
min
U
max
U
r
I
N
at U
N
V V V V mA VA/W
24
(2)
0.024 19.2 26.4 2.4 17.5 0.4/0.3
125
(110…125)
0.125 88 138 12.5 5.5 0.7/0.7
240
(24…240)
(3)
0.240 20.4 264 2.4 17.5 1.5/0.3
Input data AC, type 39.10/20/30/40/00/50/60/70
Nominal
voltage
Input
code
Operating range
Must drop-out
voltage
Rated input
current at U
N
Rated
power
U
N
U
min
U
max
U
r
I
N
at U
N
V V V V mA VA/W
230
(230…240)
8.230
184 264 23 4.2 1/0.4
Input data leakage current suppression versions, type 39.30.3/60.3
Nominal
voltage
Input
code
Operating range
Must drop-out
voltage
Rated input
current at U
N
Rated
power
The 39 Series interface modules (supply version 3) have
built-in leakage current suppression to address industry
concerns of the contacts not dropping-out when there is
residual current in the circuit; at (110…125)VAC/DC and
(230…240)VAC.
This problem can occur, for example, when connecting
the interface modules to PLC's with triac outputs or when
connecting via relatively long cables.
U
N
U
min
U
max
U
r
I
N
at U
N
V V V V mA VA/W
125
(110…125)
3.125 88 138 44 8.4 1.1/1
230
(230…240)
3.230 184 264 72 5.9 1.4/0.5
Input data AC/DC timer, type 39.80/90
Nominal
voltage
Input
code
Operating range
(AC/DC)
Must drop-out
voltage
Rated input current
at U
N
Rated power at U
N
U
N
U
min
U
max
U
r
DC AC DC AC
V V V V mA mA W VA/W
12 0.012 9.6 13.2 1.2 15 23 0.2 0.3/0.2
24
0.024