Data Sheet

22
X-2017, www.findernet.com
39 SERIES
Timed interface modules
39
SERIES
B
Output specification - Solid State Relays
L 34-1 - Output DC current v ambient temperature
39.xx.x.xxx.9024
L 34 - Output AC current v ambient temperature
39.xx.x.xxx.8240
I: SSR installed as a group (without gap between sockets)
II: SSR installed individually in free air , or with a gap ≥ 9 mm, which implies a not significant influence from nearby components
Max recommended switching frequency (Cycles/Hour, with 50% Duty-cycle) at ambient temperature 50°C, single mounting
Load 39.xx.x.xxx.9024 39.xx.x.xxx.8240 39.xx.x.xxx.7048
24V 6ADC1 180 000
24V 3ADC L/R = 10ms 5000
24V 2ADC L/R = 40ms 3600
24V 1ADC L/R = 40ms 6500
24V 0.8ADC L/R = 40ms 9000
24V 1.5ADC L/R = 80ms 3250
230V 2AAC1 60 000
230V 1.25AAC15 3600
48V 0.1ADC1 60 000