Data Sheet

23
X-2017, www.findernet.com
39
SERIES
39 SERIES
Timed interface modules
B
Timer specifications
EMC specifications
Type of test Reference standard
Electrostatic discharge
contact discharge EN61000-4-2 4kV
air discharge EN61000-4-2 8kV
Radio-frequency electromagnetic field
(80÷1000MHz) EN61000-4-3 10V/m
(1400÷2700MHz) EN61000-4-3 10V/m
Fast transients (burst) (5-50ns, 5 and 100kHz)
on Supply terminals EN61000-4-4 4kV
on control signal terminals EN61000-4-4 4kV
Surges (1.2/50μs) on supply and control
signal terminals
common mode EN61000-4-5 2kV
differential mode EN61000-4-5 0.8kV
Radio-frequency common mode
(0.15÷80MHz)
on Supply terminals EN61000-4-6 10V
on control signal terminals EN61000-4-6 3V
Radiated and conducted emission EN55022 class B
Other data
Bounce time (EMR): NO/NC ms 1/6
Vibration resistance (EMR,10...55 Hz): NO/NC g 10/15
Power lost to the environment
without contact current W 0.3
with rated current W 0.8
Terminals
Screw terminal Push-in terminal
Wire strip length mm 10 8
Screw torque Nm 0.5
Solid and stranded cable Solid and stranded cable
Min. wire size mm
2
1x0.5 1x0.5
AWG 1x21 1x21
Max. wire size mm
2
1x2.5 1x2.5
AWG 1x14 1x14
Times scales
1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5
(0.1…3)s (3…60)s (1…20)min (0.3…6)h
Functions
LED Supply voltage NO contact/output
OFF Open
ON Open
ON Open (timing to close in progress)
ON Closed