Datasheet

12
39.81
Features
Slim timed interface module, 6.2mm wide, ideal
for space-saving timing solutions in panels
Timer adjustment via top mounted rotary
knob, accessible after assembly
Control signal terminal
DIP-switch for selection of 4 time scales and 8
functions
Accepts output fuse module 093.63 (for 5 x
20 mm fuses) for quick and easy load
protection, see page 22
Common connection possible with optional
jumper links (terminals A1, A2 and 15)
1 CO (SPDT)
6/10
250/400
1,500
300
0.185
6/0.2/0.12
500 (12/10)
AgNi
12 - 24
See page 16
(0.8…1.1) U
N
0.6 U
N
0.1 U
N
(0.1...3)s, (3...60)s, (1...20)min, (0.3...6)h
± 1
≤ 50
50
5
60 · 10
3
–20...+50
IP20
6 A electromechanical relay
12 - 24 VAC/DC supply
35mm rail (EN 60715) mounting
For outline drawing see page 20
39 Series - Relay interface modules 0.1 - 2 - 6 A
AI: On-delay
DI: Interval
GI: Pulse (0.5 s) delayed
SW: Symmetrical flasher
(starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
EE: Interval with control signal off
39.81
Screw terminal
MasterTIMER - EMR
Fuse module
093.63
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage
Rated load AC1
Rated load AC15 (230 VAC)
Single phase motor rating (230 VAC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Supply specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Specified time range
Repeatability
Recovery time
Minimum control impulse
Setting accuracy – full range
Electrical life at rated load AC1
Ambient temperature range
Protection category
Approvals relay (according to type)
A
VAC
VA
VA
kW
A
mW (V/mA)
VAC/DC
VA (50 Hz)/W
%
ms
ms
%
cycles
°C
XII-2012, www.findernet.com