Datasheet

6
Technical data
Insulation according to EN 61810-1
1 pole 2 pole
Nominal voltage of supply system V AC 230/400 230/400
Rated insulation voltage V AC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8 mm) Reinforced (8 mm)
Overvoltage category III III
Rated impulse voltage kV (1.2/50 µs) 6 6
Dielectric strength V AC 4,000 4,000
Insulation between adjacent contacts
Type of insulation Basic
Overvoltage category II
Rated impulse voltage kV (1.2/50 µs) 2.5
Dielectric strength V AC 2,000
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50 µs) 1,000/1.5 1,000/1.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 EN 61000-4-4 level 4 (4 kV)
Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kV)
Other data
Bounce time: NO/NC ms 2/5
Vibration resistance (10...150)Hz: NO/NC g 20/5 (1 changeover) 14/2 (2 changeover)
Shock resistance NO/NC g 20/13 (1 changeover) 20/12 (2 changeover)
Power lost to the environment without contact current W 0.65
with rated current W 1.2 (40.11/31/51) 2 (40.61/52)
Recommended distance between relays mounted on PCB mm 5
VI-2014, www.findernet.com
40
SERIE S
40 Series - Miniature PCB/Plug-in relays 8 - 10 - 12 - 16 A
A