Datasheet

A
Contact specification
F 41 - Electrical life (AC) v contact current (monostable)
Types 41.31/61
F 41 - Electrical life (AC) v contact current (monostable)
Type 41.52
Cycles
Resistive load - cosφ = 1
Inductive load - cosφ = 0.4
limit for 41.31
Cycles
Resistive load - cosφ = 1
Inductive load - cosφ = 0.4
F 41 - Electrical life (AC) v contact current (bistable) H 41- Maximum DC1 breaking capacity
Cycles
1 pole
2 pole
DC breaking current (A)
41.61 limit current
41.31 limit current
41.52 limit current
41.52 -2 contacts in series
single contact
DC voltage (V)
Coil specifications
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥100·10
3
can be expected.
In the case of DC13 loads, the connection of a diode in parallel with the
load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
AC coil data R 41 - AC coil operating range v ambient temperature
Nominal
voltage
Coil code Operating range Resistance Rated coil
consumption
U
N
U
min
U
max
R I at U
N
V V V
Ω
mA
24 8.024 19.2 26.4 350 31.6
115 8.115 92 126.5 8100 6
230 8.230 184 253 32500 3.2
DC coil data
Nominal
voltage
Coil code Operating range Resistance Rated coil
consumption
U
N
U
min
U
max
R I at U
N
V V V
Ω
mA
5 9.005 3.5 7.5 62 80
6 9.006 4.2 9 90 66.7
12 9.012 8.4 18 360 33.3
24 9.024 16.8 36 1440 16.7
48 9.048 33.6 72 5760 8.3
60 9.060 42 90 9000 6.6
110 9.110 77 165 24200 4.5
DC coil data (bistable)
Nominal
voltage
Coil
code
Operating range Resistance Rated coil
power
U
N
Set
U
min
Reset
U
min
Set/Reset
U
max
R I at U
N
V V V V
Ω
mW
5 6.005 3.5 3.5 5.5 38 650
12 6.012 8.4 8.4 13.2 220 650
24 6.024 16.8 16.8 26.4 885 650
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 41 - DC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
X-2014, www.findernet.com
41
SERIES
6
41 Series - Low profile PCB relays