Data Sheet

6
Coil specifications
*U
min
= 0.8 U
N
for 48.61, 48.62, 48.81 and 48.82
Nominal Coil Operating range Rated coil
voltage code consumption
U
N
U
min
U
max
I at U
N
(50Hz)
VVVmA
12 8.012 9.6 13.2 90.5
24 8.024 19.2 26.4 46
110 8.110 88 121 10.1
120 8.120 96 132 11.8
230 8.230 184 253 7.0
AC coil data
Nominal Coil Operating range Rated coil
voltage code consumption
U
N
U
min
*
U
max
I at U
N
VVVmA
12 7.012 8.8 18 41
24 7.024 17.5 36 22.2
125 7.125 91 188 4
DC coil data (0.5 W sensitive)
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 48 - AC coil operating range v ambient temperatureR 48 - DC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
48.31/52/72
1
2
48.31/52/72
48.61/62/81/82
48.61/62/81/82
1
2
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 48 - DC coil operating range v ambient temperature
Type 48.12
Nominal Coil Operating range Resistance Rated coil
voltage code
consumption
U
N
U
min
U
max
R I at U
N
VVVΩ mA
12 9.012 9 14.4 205 58.5
24 9.024 18 28.8 820 29.3
DC coil data, 2 pole relay - Type 48.12
II-2014, www.findernet.com
48
SERIE S
48 Series - Relay interface modules 8 - 10 - 16 A
B