Data Sheet

B
Contact specification
F 48 - Electrical life (AC) v contact current
Types 48.P3/P6/31/61
F 48 - Electrical life (AC) v contact current
Types 48.P8/62
Cycles
limit for 48.31
Resistive load - cosϕ = 1
Inductive load- cosϕ = 0.4
12
8
Cycles
Resistive load - cosϕ = 1
Inductive load AC15
F 48 - Electrical life (AC) v contact current
Types 48.P5/52
F 48 - Electrical life (AC) v contact current
Type 48.12/32
Cycles
Resistive load - cosϕ = 1
Inductive load- cosϕ = 0.4
Cycles
Resistive load - cosϕ = 1
Inductive load- cosϕ = 0.4
H 48 - Maximum DC1 breaking capacity
Types 48.P3/P5/P6/31/52/61
H 48 - Maximum DC1 breaking capacity
Types 48.P8/62
DC breaking current (A)
DC voltage (V)
2 contacts in series
single contact
48.P6/61 current limit
48.P3/31 current limit
48.P5/52 current limit
DC breaking current (A)
DC voltage (V)
2 contacts in series
single contact
H 48 - Maximum DC1 breaking capacity
Type 48.12/32
DC breaking current (A)
DC voltage (V)
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of ≥100·10
3
can be expected.
In the case of DC13 loads, the connection of a diode in parallel with the
load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
9
VII-2018, www.findernet.com
48
SERIES
48 SERIES
Relay interface modules 8 - 10 - 16A