Datasheet

3
B
58 SERIES
Relay interface modules 7 - 10A
58
SERIES
Contact specification
F 58 - Electrical life (AC) v contact current
2 & 3 pole relays
F 58 - Electrical life (AC) v contact current
4 pole relay
Resistive load - cosφ = 1
Inductive load - cosφ = 0.4
Cycles
Cycles
Resistive load - cosφ = 1
Inductive load - cosφ = 0.4
H 58 - Maximum DC1 breaking capacity
2 & 3 pole current limit
4 pole current limit
contacts in series
DC breaking current (A)
1 2 3 4
DC voltage (V)
When switching a resistive load (DC1) having voltage and current values
under the curve, an electrical life of ≥100·10
3
can be expected.
In the case of DC13 loads, the connection of a diode in parallel with the
load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
Coil specifications
DC coil data
Nominal
voltage
Coil code Operating range Resistance Rated coil
absorption
U
N
U
min
U
max
R I at U
N
V V V
Ω
mA
12 9.012 9.6 13.2 140 86
24 9.024 19.2 26.4 600 40
48 9.048 38.4 52.8 2400 20
125 9.125 100 138 17300 7.2
AC coil data
Nominal
voltage
Coil code Operating range Resistance Rated coil
absorption
U
N
U
min
U
max
R I at U
N
(50Hz)
V V V
Ω
mA
12 8.012 9.6 13.2 50 97
24 8.024 19.2 26.4 190 53
48 8.048 38.4 52.8 770 25
110 8.110 88 121 4000 12.5
120 8.120 96 132 4700 12
230 8.230 184 253 17000 6
R 58 - DC coil operating range v ambient temperature R 58 - AC coil operating range v ambient temperature
1
2
1
2
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.