Data Sheet

A
Ordering information
Example: 62 series power relay + Faston 250 (6.3x0.8mm), rear flange mount, 2 NO (DPST-NO), 12VDC coil.
A B C D
6 2 . 8 2 . 9 . 0 1 2 . 0 3 0 0
Series
Type
2 = PCB
3 = Plug-in
8 = Faston 250 (6.3x0.8mm)
with rear flange mount
No. of poles
1 = 1 pole (double break)
2 = 2 pole
3 = 3 pole
Coil version
8 = AC (50/60Hz)
9 = DC
Coil voltage
See coil specifications
A: Contact material
0 = Standard AgCdO
4 = AgSnO
2
(standard
for versions 4800)
B: Contact circuit
0 = CO (nPDT)
3 = NO (nPST),
≥3mm contact gap
5 = CO (nPDT) + additional physical
separator between coil and contacts
(for SELV applications)
6 = NO (nPST), ≥3mm contact gap
+ additional physical separator
between coil and contacts (for SELV
applications)
8 = NO (1 pole double break or 2pole)
with magnetic blow
D: Special versions
0 = Standard
6 = Rear flange mount
9 = Type 62.82/83 without rear flange
mount
C: Options
0 = None
2 = Mechanical indicator
3 = LED (AC)
4 = Lockable test button +
mechanical indicator
5* = Lockable test button + LED (AC)
54* = Lockable test button + LED (AC) +
mechanical indicator
6* = LED + diode
(DC, polarity positive to pin A/A1)
7* = Lockable test button + LED + diode
(DC, polarity positive to pin A/A1)
74* = Lockable test button + LED + diode
(DC, polarity positive to pin A/A1)
+ mechanical indicator
* Options not available for 220VDC and
400VAC versions.
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type Coil version A B C D
62.22/23 AC-DC 0 - 4 0 - 3 - 5 - 6 0 0
62.32/33 AC-DC 0 - 4 0 - 3 - 5 - 6 0 0 - 6
AC-DC 0 - 4 0 - 5 2 - 4 0 - 6
AC 0 - 4 0 2 - 3 - 4 - 5 0 - 6
AC 0 - 4 0 - 3 3 0 - 6
AC 0 - 4 0 54 /
DC 0 - 4 0 4 - 6 - 7 0 - 6
DC 0 - 4 0 - 3 6 0 - 6
DC 0 - 4 0 74 /
62.31/32 DC 4 8 0 0
62.82/83 AC-DC 0 - 4 0 - 3 - 5 - 6 0 0 - 9
AC-DC 0 - 4 0 - 5 2 - 4 0
AC 0 - 4 0 2 - 3 - 4 - 5 0
AC 0 - 4 0 - 3 3 0
DC 0 - 4 0 4 - 6 - 7 0
DC 0 - 4 0 - 3 6 0
Descriptions: Options and Special versions
C: Option 3, 5, 54
LED (AC)
C: Option 6, 7, 74
LED + diode (DC, polarity
positive to pin A/A1)
B: Contact circuit 5, 6
Additional physical separator
between coil and contacts
(forSELV applications)
B: Contact circuit 8
Magnetic blow
Lockable test button and mechanical flag indicator (0040, 0050, 0054, 0070, 0074)
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when
the test button is pushed, the contacts operate. When the test button is released the contacts return
to their former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition
to the above function), when the test button is pushed and rotated, the contacts are latched in
the operating state, and remain so until the test button is rotated back to its former position.
In both cases ensure that the test button actuation is swift and decisive.
1
2
3
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
7
II-2018, www.findernet.com
62
SERIES
62 SERIES
Power relays 16A