Data Sheet

A
Technical data
Insulation according to EN61810-1
2 CO - 3 CO 2 NO - 3 NO 1 NO* 2 NO*
Nominal voltage of supply system VAC 230/400 230/400 230/400 230/400
Rated insulation voltage VAC 400 400 400 400
Pollution degree 3 3 3 3
Insulation between coil and contact set
Type of insulation Reinforced Reinforced Reinforced Reinforced
Overvoltage category III III III III
Rated impulse voltage kV (1.2/50µs) 6 6 6 6
Dielectric strength VAC 4000 4000 4000 4000
Insulation between adjacent contacts
Type of insulation Basic Basic Basic
Overvoltage category III III III
Rated impulse voltage kV (1.2/50µs) 4 4 4
Dielectric strength VAC 2500 2500 2500
Insulation between open contacts
Type of disconnection
Micro-disconnection
Full-disconnection Full-disconnection
Full-disconnection**
Overvoltage category III III II
Rated impulse voltage kV (1.2/50µs) 4 4 2.5
Dielectric strength VAC/kV (1.2/50µs) 1500/2 3000/4 3000/4 2000/2.5
Conducted disturbance immunity
Burst (5...50)ns, 5 kHz, on A1 - A2 according to EN61000-4-4 level 4 (4kV)
Surge (1.2/50µs) on A1 - A2 (differential mode) according to EN61000-4-5 level 4 (4kV)
Other data
Bounce time: NO/NC ms 1/5
(changeover)
3/—
(normally open)
3/—
(normally open)
3/—
(normally open)
Vibration resistance (10…150)Hz: NO/NC g 20/8
Shock resistance g 15
Power lost to the environment 2 pole (CO) 3 pole (CO) 2 pole (NO) 3 pole (NO) 1 pole (NO)* 2 pole (NO)*
without contact current W 1.3 1.3 3 3 1.3 1.3
with rated current W 3.3 4.3 5 6 3 3.3
Recommended distance between relays mounted on PCB mm ≥ 5
* Magnetic blow version
** Only in applications where over voltage category II is permitted. In applications of over voltage category III: Micro-disconnection.
8
II-2018, www.findernet.com
62 SERIES
Power relays 16A
62
SERIES