Data Sheet
A
Contact specification
F 62 - Electrical life (AC) v contact current
Cycles
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
H 62 - Maximum DC1 breaking capacity
Changeover contacts
Voltage DC (V)
DC breaking current (A)
contacts in series
H 62 - Maximum DC1 breaking capacity
Normally open contacts
Voltage DC (V)
DC breeaking current (A)
contacts in series
• When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥100·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load.
Note: the release time of the load will be increased.
H 62 - Maximum DC breaking capacity 62.31.9.xxx.4800
20
60
100 140
180
220 260
0.1
1
10
50
(V)
Voltage DC (V)
DC breaking current (A)
DC1
DC13
L/R = 40 ms
H 62 - Maximum DC breaking capacity 62.32.9.xxx.4800
20
60
100 140
180
220
0.1
1
10
(V)
260
50
Voltage DC (V)
DC breeaking current (A)
DC1
DC13
L/R = 40 ms
• When switching a resistive load (DC1), or a DC13 load with a diode in parallel to the load, having voltage and current values under the DC1 curve, an
electrical life of ≥100·10
3
can be expected. Note: the release time for the load will be increased.
• When switching a DC13 load without a diode in parallel to the load, the DC13 curve applies and an electrical life of ≥80·10
3
can be expected.
9
II-2018, www.findernet.com
62
SERIES
62 SERIES
Power relays 16A