Data Sheet

II-2018www.findernet.com
4
A
65 SERIES
Power relays 20 - 30A
65
SERIES
30A Power relays
1 NO (SPST-NO)
Type 65.31-0300
- Flange mount and Faston 250 connections
Type 65.61-0300
- PCB mount
≥3mm contact gap
AC coils & DC coils
Cadmium Free option available
65.31-0300 65.61-0300
30A rated contacts
Faston 250 (6.3x0.8mm)
connection
Flange mount
30A rated contacts
PCB mount
Bifurcated terminals
Copper side view
* Distance between contacts ≥3mm
(EN60335-1).
** With the AgSnO
2
material the maximum peak
current is 120A- 5ms on NO contact.
For UL ratings see:
“General technical information” page V
For outline drawing see page 7
Contact specification
Contact configuration 1 NO (SPST-NO), ≥3mm* 1 NO (SPST-NO), ≥3mm*
Rated current/Maximum peak current A 30/50** 30/50**
Rated voltage/
Maximum switching voltage VAC 250/400 250/400
Rated load AC1 VA 7500 7500
Rated load AC15 (230VAC) VA 1250 1250
Single phase motor rating (230VAC) kW 1.5 1.5
Breaking capacity DC1: 30/110/220V A 30/1.1/0.7 30/1.1/0.7
Minimum switching load mW (V/mA) 1000 (10/10) 1000 (10/10)
Standard contact material AgCdO AgCdO
Coil specification
Nominal voltage (U
N
) VAC (50/60Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
VDC 6 - 12 - 24 - 48 - 60 - 110 -125 - 220
Rated power AC/DC VA (50Hz)/W 2.2/1.3 2.2/1.3
Operating range AC (0.8…1.1)U
N
(0.8…1.1)U
N
DC (0.85…1.1)U
N
(0.85…1.1)U
N
Holding voltage AC/DC 0.8U
N
/0.6U
N
0.8U
N
/0.6U
N
Must drop-out voltage AC/DC 0.2U
N
/0.1U
N
0.2U
N
/0.1U
N
Technical data
Mechanical life AC/DC cycles 10·10
6
/30·10
6
10·10
6
/30·10
6
Electrical life at rated load AC1 cycles 50·10
3
50·10
3
Operate/release time ms 15/4 15/4
Insulation between coil
and contacts (1.2/50μs) kV 4 4
Dielectric strength
between open contacts VAC 2500 2500
Ambient temperature range °C –40…+75 –40…+75
Environmental protection RT I RT I
Approvals (according to type)