Data Sheet

II-2018www.findernet.com
5
A
65
SERIES
65 SERIES
Power relays 20 - 30A
Ordering information
Example: 65 series power relay, PCB with bifurcated terminals, 1 NO + 1 NC (SPST-NO + SPST-NC) contact, 12VDC coil.
A B C D
6 5 . 6 1 . 9 . 0 1 2 . 0 0 0 0
Series
Type
3 = Faston 250 (6.3x0.8mm)
with rear flange mount
6 = PCB with bifurcated terminals
No. of poles
1 = 1 NO + 1 NC (SPST-NO + SPST-NC)
Coil version
8 = AC (50/60Hz)
9 = DC
Coil voltage
See coil specifications
A: Contact material
0 = Standard AgCdO
4 = AgSnO
2
B: Contact circuit
0 = 1 NO + 1 NC
(SPST-NO + SPST-NC)
3 = NO (≥3mm contact gap)
D: Special versions
0 = Standard
9 = Type 65.31 without rear flange
mount
C: Options
0 = None
Selecting features and options: only combinations in the same row are possible.
Preferred selections for best availability are shown in bold.
Type Coil version A B C D
65.31 AC-DC 0 - 4 0 - 3 0 0 - 9
65.61 AC-DC 0 - 4 0 - 3 0 0
Technical data
Insulation according to EN61810-1
1 NO + 1 NC 1 NO
Nominal voltage supply system VAC 230/400 230/400
Rated insulation voltage VAC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Basic Basic
Overvoltage category III III
Rated impulse voltage kV (1.2/50μs) 4 4
Dielectric strength VAC 2500 2500
Insulation between open contacts
Type of disconnection Micro-disconnection Full-disconnection
Overvoltage category III
Rated impulse voltage kV (1.2/50μs) 4
Dielectric strength VAC/kV (1.2/50μs) 1500/2 2500/4
Insulation between coil terminals
Rated impulse voltage (surge) differential mode
(according to EN 61000-4-5) kV (1.2/50µs) 4
Other data
Bounce time: NO/NC ms
5/6 (1 NO + 1 NC) 7/— (1 NO)
Vibration resistance (10…150)Hz: NO/NC g 20/13
Shock resistance g 20
Power lost to the environment without contact current W 1.3
with rated current W 2.1 (65.31, 65.61) 3.1 (65.31/.61.0300)
Recommended distance between relays mounted on PCB mm ≥5