Data Sheet

2
II-2014, www.findernet.com
67.22-4500 67.23-4500
2 NO (DPST-NO) 3 NO (3PST-NO)
≥ 5.2 ≥ 5.2
50/150 50/150
400/690 400/690
20,000 20,000
2,300 2,300
22
—7
50/7/2 50/7/2
1,000 (10/10) 1,000 (10/10)
AgSnO
2
AgSnO
2
5 - 6 - 8 - 12 - 24 - 48 - 60 - 110
2.7 2.7
(0.90 …1.1) U
N
(0.90 …1.1) U
N
(0.95…2.5) U
N
(0.95…2.5) U
N
(0.25...0.5) U
N
(0.25...0.5) U
N
0.17 0.17
0.05 U
N
0.05 U
N
1 · 10
6
1 · 10
6
30 · 10
3
30 · 10
3
30/4 30/4
–40...+60 (–40...+85) –40...+60 (–40...+85)
RTII RTII
Copper side view
Copper side view
2 NO
Contact gap ≥ 5.2 mm
PCB mount
Features
Printed circuit mount - 5.2 mm contact gap
50 A Power relay for photovoltaic inverters
2 and 3 pole versions
(NO double break contacts)
Contact gap ≥ 5.2 mm (according to
VDE 0126-1-1, EN 62109-1, EN 62109-2)
Suitable for inverters with DC input up to
1,500 V and AC output up to 690 V,
installations up to 4,000 m above sea level
DC coils, with only 170 mW holding power
Reinforced insulation between coil and contacts
1.5 mm gap between PCB and relay base
Suitable for use at ambient temperatures up to
85 °C (with energy-saving coil energization)
or 60 °C (with standard coil energization)
Meets the EN 60335-1 requirements of
resistance to heat and fire (GWIT 775 °C and
GWFI 850 °C)
3 NO
Contact gap ≥ 5.2 mm
PCB mount
Contact specification
Contact configuration
Contact gap mm
Rated current/Maximum peak current (for 5 ms) A
Rated voltage/Maximum switching voltage V AC
Rated load AC1/AC7a (per pole) VA
Rated load AC15 (per pole @ 230 V AC) VA
Single-phase motor rating (230 V AC) kW
Three-phase motor rating (480 V AC) kW
Breaking capacity DC1: 24/110/220 A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
)V DC
Rated power W
Operating range (–40…+60°C) DC
Energy-saving mode (–40...+85)°C
Operating range for 1s
Holding voltage range DC
Minimum holding power W
Must drop-out voltage DC
Technical data
Mechanical life cycles
Electrical life at rated load AC7a cycles
Operate/release time ms
Ambient temperature range (energy-saving mode) °C
Environmental protection
Approvals (according to type)
For outline drawing see page 6
67
SERIE S
67 Series - Solar relay 50 A