Monitoring relays 10 A 71 SЕRIES Industrial motors Industrial refrigerators Elevators and lifts Textile machines Labelling machines Carousel warehouses
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
71 SERIES Monitoring relays 10 A 71 SERIES 71.11.8.230.0010 1 - Phase 230 V Over & Under voltage monitoring relays 71.11.8.230.1010 71.11.8.230.0010 - Fixed Over & Under voltage detection - Link selectable 5 or 10 minute lock-out delay 71.11.8.230.
71 SERIES 71 SERIES Monitoring relays 10 A 71.31.8.400.1010 3 - Phase 400 V Over & Under voltage monitoring relay 71.31.8.400.
71 SERIES Monitoring relays 10 A 71 SERIES 71.31.8.400.1021 3 - Phase 400 V - Line monitoring relays 71.31.8.400.2000 71.31.8.400.1021 - Over & Under voltage trip on-delay - Fault memory 71.31.8.400.
71 SERIES 71 SERIES Monitoring relays 10 A 71.41.8.230.1021 Universal voltage or current detecting and monitoring relay 71.51.8.230.1021 71.41.8.230.1021 - Voltage monitoring 71.51.8.230.
1 SERIES Monitoring relays 10 A 71 SERIES 71.91.x.xxx.0300 Thermistor temperature sensing relays for industrial applications 71.92.x.xxx.0001 71.91 - 1 Pole, without fault memory 71.
71 SERIES 71 SERIES Monitoring relays 10 A Ordering information Example: Universal voltage monitoring relay with LCD display for AC/DC voltage detection, 1 CO (SPDT) contact rated 10 A 250 V, supply voltage 230 V, programmable delay time and fault memory. 7 1 . 4 Series Type 1 = 1 phase AC line monitoring 3 = 3 phase AC line monitoring 4 = AC/DC universal- Voltage detection 5 = AC/DC universal- Current detection 9 = Thermistor relay (temperature monitoring with PTC thermistor) No.
71 SERIES Monitoring relays 10 A 71 SERIES Technical data Insulation Insulation according to EN 61810-1 insulation rated voltage rated impulse withstand voltage V 250 kV 4 pollution degree 3 over-voltage category III V AC 2500 kV (1.
X-2017,www.findernet.com 71.11.8.230.0010 E 71.11.8.230.1010 71.31.8.400.1010 71.31.8.400.1021 71.31.8.400.2000 71.41.8.230.1021 Current transformer 10 • • 71.51.8.230.1021 71.91.0.024.0300 71.91.8.230.0300 71.92.0.024.0001 71.92.8.230.0001 • • • • • • 1 CO SPDT • • • • 1 CO SPDT • • • • • 1 CO SPDT • • • • 1 CO SPDT • • 1 CO SPDT • • 1 CO SPDT • • 1 CO SPDT • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Module width Relay contact, 250 V AC/10 A 22.
71 SERIES Monitoring relays 10 A 71 SERIES Explanation of relay marking and LED/LCD display Monitoring relay without LCD-display ON LED green steady light: supply voltage is on and measuring system is active. DEF Default: the detected value is outside of the acceptable range (asymmetric is shown by the LED ASY). LED red flashing: delay time is running, see the function diagram. LED red steady light: output relay is off, contact 11-14 (6-2) is open. Phase asymmtery is outside of the predefined range.
71 SERIES 71 SERIES Monitoring relays 10 A LED/LCD status announcement/advice Type 71.11.8.230.0010 71.11.8.230.1010 71.31.8.400.1010 Starting mode After connecting T = 5 or 10 min 11-14 open 71.31.8.400.
71 SERIES Monitoring relays 10 A 71 SERIES Functions Type 71.11.8.230.0010 Switch off Immediately if monitored value is outside of the set points. Fixed limits Switch on After expiry of the time T and if monitored value is within the set points. C = output contact Normally open 11-14 (6-2) closed. Switch off Immediately if monitored value is outside of the set points. Type 71.11.8.230.1010 Switch on After expiry of the time T and if monitored value is within the set points.
71 SERIES Monitoring relays 10 A 71 SERIES Functions Type 71.31.8.400.2000 Switch off Phase asymmetry Incorrect phase rotation Phase loss U= 400 V AC 3 ~ (50/60 Hz ) L1 L2 L3 A1 1 3 A2 5 7 A3 9 LED • ASY yellow Phase asymmetry LED • DEF red Voltage to A1 (1) and/or A2 (5) > 1.11 UN 3~U ASY 2 4 14 12 6 8 11 LED • ON green Monitoring system is active and 400 V supply voltage is connected to 1-5 or A1-A2. 10 C = output contact Normally open 11-14 (6-2) closed.
71 SERIES Monitoring relays 10 A 71 SERIES Functions Type 71.51.8.230.1021 Switch off ILo – mode If the monitored value is less than the lower-limit and, time T1 has expired. Programmable IUp – mode If the monitored value is higher than the upper limit, and time T1 has expired. MEMORY ON MEMORY OFF ILo IUp – mode If the monitored value of voltage is outside of the upper or lower limits, and time T1 has expired.
71 SERIES 71 SERIES Monitoring relays 10 A Functions Switch off ––Thermistor line break ––Over temperature RPTC > (2.5…3.6)kΩ, ––Thermistor line short circuit (RPTC < 20 Ω) ––Loss of supply Type 71.92.x.xxx.0001 MEMORY OFF Switch on Temperature within limits (20 Ω…2.5 kΩ) on power-up. RPTC > (1…1.5)kΩ on cooling. MEMORY ON Select MEMORY OFF If monitored value is expected to cross the resetting threshold.