Datasheet

83.01 83.02 83.52
1 CO (SPDT) 2 CO (DPDT) 2 CO (DPDT)
16/30 12/30 12/30
250/400 250/400 250/400
4,000 3,000 3,000
750 750 750
0.5 0.5 0.5
16/0.3/0.12 12/0.3/0.12 12/0.3/0.12
300 (5/5) 300 (5/5) 300 (5/5)
AgNi AgNi AgNi
24…240 24...240 24...240
24…240 24...240 24...240
< 1.5 / < 2 < 2 / < 2 < 2 / < 2
16.8...265 16.8...265 16.8...265
16.8...265 16.8...265 16.8...265
(0.05…1)s, (0.5…10)s, (0.05…1)min, (0.5...10)min, (0.05...1)h, (0.5...10)h, (0.05...1)d, (0.5...10)d
± 1 ± 1 ± 1
200 200 200
50 50 50
± 5 ± 5 ± 5
50·10
3
60·10
3
60·10
3
–20…+60 –20…+60 –20…+60
IP 20 IP 20 IP 20
Wiring diagram
(without control signal)
Multi-voltage
Multi-function
Timing can be regulated using
ext. Potentiometer
2 timed contacts or 1 timed +
1 instantaneous contact
Multi-voltage
Multi-function
Timing can be regulated using
ext. Potentiometer
2 timed contacts or 1 timed +
1 instantaneous contact
3 functions with pause option
Multi-voltage
Multi-function
AI: On-delay
DI: Interval
GI: Pulse delayed
SW: Symmetrical flasher (starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
WD: Watchdog (Retriggerable interval
with control signal on)
AI: On-delay
DI: Interval
GI: Pulse delayed
SW: Symmetrical flasher (starting pulse on)
BE: Off-delay with control signal
CE: On- and off-delay with control signal
DE: Interval with control signal on
WD: Watchdog (Retriggerable interval
with control signal on)
AE: On-delay with control signal
EEa: Interval with control signal off
(retriggerable)
FE: Interval with control signal on and off
GE: Pulse delayed with control signal on
IT: Timing step
BEp: Off-delay with control signal and
pause signal
DEp: Interval with control signal on and
pause signal
SHp: “Shower” function
Wiring diagram
(with control signal)
(with control signal)
(without control signal)
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range V AC
V DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load in AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
1
Features
Multi-function timer range
83.01 - Multi-function & multi-voltage, 1 Pole
83.02 - Multi-function & multi-voltage,
2 Pole (timed + instantaneous options),
external time setting potentiometer
option
83.52 - Multi-function & multi-voltage,
2 Pole (timed + instantaneous options),
external time setting potentiometer
option, pause function option
22.5 mm wide
Eight time scales from 0.05s to 10 days
High input/output isolation
Wide supply range (24...240)V AC/DC
35 mm rail (EN 60715) mount
“Blade + cross” - both flat blade and cross
head screw drivers can be used to adjust the
range and function selectors, the timing
trimmer, and to disengage the rail mounting
clip
Multi-voltage versions with “PWM clever”
technology
For outline drawing see page 5
I-2015, www.findernet.com
Wiring
diagram
Wiring
diagram
(with control signal and external
potentiometer connection)
Wiring
diagram
(with control signal and pause signal)
Wiring
diagram
83 Series - Modular timers 12 - 16 A
83
SERIES
H

Summary of content (10 pages)