3
83.62 83.82 83.91
• Multi-voltage
• Multi-function
LI: Asymmetrical flasher
(starting pulse on)
LE: Asymmetrical flasher (starting
pulse on) with control signal
PI: Asymmetrical flasher
(starting pulse off)
PE: Asymmetrical flasher (starting
pulse off) with control signal
Wiring diagram
(with control signal)
2 CO (DPDT) 2 NO (DPST-NO) 1 CO (SPDT)
8/15 16/30 16/30
250/400 250/400 250/400
2,000 4,000 4,000
400 750 750
0.3 0.5 0.5
8/0.3/0.12 16/0.3/0.12 16/0.3/0.12
300 (5/5) 300 (5/5) 300 (5/5)
AgNi AgNi AgNi
24...240 24...240 24...240
24...220 24...240 24...240
< 1.5 / < 2 < 1.5 / < 2 < 1.5 / < 2
16.8...265 16.8...265 16.8...265
16.8...242 16.8...265 16.8...265
* **
± 1 ± 1 ± 1
— 200 200
500 ms (A1 - A2) — 50
± 5 ± 5 ± 5
100·10
3
50·10
3
50·10
3
–20…+60 –20…+60 –20…+60
IP 20 IP 20 IP 20
• Multi-voltage
• Mono-function
• 2 pole
BI: Power off-delay (True off-delay)
Wiring diagram
(without control signal)
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range V AC
V DC
Technical data
Specified time range
Repeatability %
Recovery time ms
Minimum control impulse ms
Setting accuracy-full range %
Electrical life at rated load in AC1 cycles
Ambient temperature range °C
Protection category
Approvals (according to type)
Features
Mono-function and multi-function timer range
83.62 - Power off-delay, multi-voltage, 2 Pole
83.82 - Star-Delta, multi-voltage,
star and delta output contacts
83.91 - Asymmetrical flasher, multi-voltage,
1 Pole
• 22.5 mm wide
• Time scales:
Type 83.62 - 0.05s to 3 minutes
Type 83.82 / 83.91 - 0.05 s to 10 days
• Wide supply range (24…240)V AC / DC
• 35 mm rail (EN 60715) mount
Wiring diagram
(without control signal)
Wiring diagram
(without control signal)
• Multi-voltage
• Mono-function
• 2 pole
• Transfer time can be
regulated (0.05…1)s ***
SD: Star-delta
* (0.05…2)s, (1…16)s, (8…70)s, (50…180)s
** (0.05…1)s, (0.5…10)s, (0.05…1)min,
(0.5...10)min, (0.05...1)h, (0.5...10)h,
(0.05...1)d, (0.5...10)d
*** 0.05 s, 0.2 s, 0.3 s, 0.45 s, 0.6 s, 0.75 s,
0.85 s, 1 s
For outline drawing see page 5
I-2015, www.findernet.com