SMARTimer, digital timer 16 A Timers and lighting controls 84 SЕRIES Automatic car-washes Labelling machines Punches, cleaners, planers and sanders Industrial furnaces and ovens Discotheques, swimming pools and fountains
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
84 SERIES SMARTimer 16 A 84 SERIES Multi-function SMARTimer Type 84.
84 SERIES SMARTimer 16 A 84 SERIES Ordering information Example: 84 series, SMARTimer, 2 CO - 16 A, supply rated at (110…240)V AC/DC. 8 4 . 0 2 . 0 . 2 3 0 . 0 Series 0 0 0 Versions 0 = Standard Type 0 = 2 Channel multi-function SMARTimer Supply voltage 230 = (110…240)V AC/DC (not polarized) 024 = (12…24)V AC/DC (not polarized) Supply version 0 = AC (50/60 Hz)/DC No. of poles 2 = 2 CO (DPST) Technical data Insulation Dielectric strength Screw torque Max.
84 SERIES SMARTimer 16 A 84 SERIES Outline drawings 84.02 Screw terminal Two programming modes “Smart” “Classic” Mode via smartphones with NFC communication using Finder toolbox Android App. Mode via the joystick H Android, Google Play and the Google Play logo are trademarks of Google Inc. Finder Toolbox for reference Finder Toolbox provides all technical data sheets and news from Finder. IX-2016, www.findernet.
84 SERIES 84 SERIES SMARTimer 16 A Functions Wiring diagram Type 84.02 (OFF) Relay OFF. The output contact stays permanently open. (ON) Relay ON. The output contact stays permanently closed. 18 16 15 (AI) On-delay. Apply power to timer. Output contact transfers after preset time has elapsed. Reset occurs when power is removed. 28 26 25 U (DI) Interval. Apply power to timer. Output contact transfers immediately. After the preset time has elapsed, contact resets. (GI) Pulse delayed.
84 SERIES SMARTimer 16 A 84 SERIES Functions Wiring diagram Type 84.02 18 16 15 28 26 25 (FE) Interval with control signal on and off. Power is permanently applied to the timer. Both the opening and the closing of the Signal Switch (S) initiates the transfer of the output contact (or extends the time). In both instances the contact resets after the preset delay has elapsed. (EEa) Interval with control signal off (retriggerable) Power is permanently applied to the timer.
4 SERIES 84 SERIES SMARTimer 16 A Functions Wiring diagram Type 84.02 18 16 15 (SHp) "Shower" (off-delay with control signal and pause signal). Power is permanently applied to the timer. The output contact transfers immediately on closure of the Signal Switch (S). Opening the signal switch initiates the preset delay, after which the output contact resets. Closure of the Pause Switch (P) will immediately halt the timing process, but the elapsed time will be retained.