Data Sheet
060.72
6
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
Typical application with current sensing relays.
An open circuit filiment of lamp L
1 is detected by the current sensing
relay coil (K
1) which causes the back-up safety lamp L2 to be energised,
and indication of failure at the control panel via lamp S1.
Example: navigation light.
L
1 = Light
L
2 = Safety light
S1 = Control light
K1 = Relay
Coil specifications
Current sensing version
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 60 - AC coil operating range v ambient temperatureR 60 - DC coil operating range v ambient temperature
L
N
Coil code I
min
(A) I
N
(A) I
max
(A) R (Ω)
4251 2.1 2.5 3.0 0.05
4181 1.5 1.8 2.2 0.10
4161 1.4 1.6 1.9 0.12
4121 1.0 1.2 1.4 0.22
4101 0.85 1.0 1.2 0.32
4051 0.42 0.5 0.6 1.28
4041 0.34 0.4 0.5 2.00
4031 0.25 0.3 0.4 3.57
4021 0.17 0.2 0.25 8.0
4011 0.085 0.1 0.15 32.1
Current sensing AC coil data
Coil code I
min
(A) I
N
(A) I
max
(A) R (Ω)
4202 1.7 2.0 2.4 0.15
4182 1.5 1.8 2.2 0.19
4162 1.4 1.6 1.9 0.24
4142 1.2 1.4 1.7 0.31
4122 1.0 1.2 1.4 0.42
4102 0.85 1.0 1.2 0.61
4092 0.8 0.9 1.1 0.75
4062 0.5 0.6 0.7 1.70
4032 0.25 0.3 0.4 6.70
4012 0.085 0.1 0.15 61
Current sensing DC coil data
Other types of current sensing relays are available on request.
60 Series - General purpose relays 6 - 10 A
Sheet of marker tags for relay types 60.12 and 60.13, plastic, 72 tags, 6x12 mm 060.72
Accessories