Datasheet

60.12 60.13
2 CO (DPDT) 3 CO (3PDT)
10/20 10/20
250/400 250/400
2,500 2,500
500 500
0.37 0.37
10/0.4/0.15 10/0.4/0.15
500 (10/5) 500 (10/5)
AgNi AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
2.2/1.3 2.2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
20 · 10
6
/50 · 10
6
200 · 10
3
200 · 10
3
11/4 11/4
43.6
1,000 1,000
–40…+70 –40…+70
RT I RT I
2 pole, 10 A power contacts
8 pin plug-in
3 pole, 10 A power contacts
11 pin plug-in
Contact specification
Contact configuration
Rated current/Maximum peak current A
Rated voltage/Maximum switching voltage V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Single phase motor rating (230 V AC) kW
Breaking capacity DC1: 30/110/220 V A
Minimum switching load mW (V/mA)
Standard contact material
Coil specification
Nominal voltage (U
N
) V AC (50/60 Hz)
V DC
Rated power AC/DC VA (50 Hz)/W
Operating range AC
DC
Holding voltage AC/DC
Must drop-out voltage AC/DC
Technical data
Mechanical life AC/DC cycles
Electrical life at rated load AC1 cycles
Operate/release time ms
Insulation between coil and contacts (1.2/50
µ
s)
kV
Dielectric strength between open contacts V AC
Ambient temperature range °C
Environmental protection
Approvals (according to type)
1
Features
Plug-in mount
10 A General purpose relay
2 & 3 pole changeover contacts
Cadmium Free contacts (preferred version)
AC coils & DC coils
UL Listing (certain relay/socket combinations)
Contact material options
Lockable test button with mechanical flag
indicator (preferred version)
90 series sockets
Coil EMC suppression
Timer accessories 86 series
European Patent
FOR UL RATINGS SEE:
“General technical information” page V