40 SЕRIES Miniature PCB Relays 8 - 10 - 12 - 16 A Medical and dentistry Control panels Panels for electrical distribution Toys Automation for blinds, grilles and shutters Door and gate openers Electronic circuit boards Vending machines
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A Power relays 1 and 2 pole for direct PCB or socket mount Type 40.31/51 -- 1 CO 12 A (3.5 mm pin pitch) -- 1 CO 12 A (5.0 mm pin pitch) Type 40.52 -- 2 CO 8 A (5.0 mm pin pitch) Type 40.61 -- 1 CO 16 A (5.0 mm pin pitch) • Pin length 3.5 mm for PCB mount • Pin length 5.3 mm for Plug-in mount • DC coils (650 mW or 500 mW) • Cadmium-free contact material available • 8 mm Creepage and Clearance, 6 kV (1.
0 SERIES 40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40.31/51 Power relays 1 and 2 pole for direct PCB or socket mount 40.61 Type 40.31/51 -- 1 CO 10 A (3.5 mm pin pitch) -- 1 CO 10 A (5.0 mm pin pitch) Type 40.52 -- 2 CO 8 A (5.0 mm pin pitch) Type 40.61 -- 1 CO 16 A (5.0 mm pin pitch) • AC or DC coils according to type • Cadmium-free contact material • 8 mm Creepage and Clearance, 6 kV (1.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Power relays 1 and 2 pole for direct PCB or socket mount 40.xx.6 40.62 40.11 Type 40.62 - 2 CO 10A (5.0 mm pin pitch) - DC coils (650 mW or 500 mW) - Meets EN 60335-1 glow wire requirements A Type 40.11 -- 1 CO 10 A - flat pack -- DC (sensitive) coils Type 40.xx.6 -- Bistable versions of the types 40.31, 40.51, 40.52 and 40.61 -- Bistable (single coil) • Cadmium-free contact material available • 8 mm Creepage and Clearance, 6 kV (1.
40 SERIES 40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A Ordering information Example: 40 series PCB relay, 2 CO, 230 V AC coil. A 4 0 . 5 A B C D 2 . 8 . 2 3 0 . 0 0 0 0 A: Contact material See table below Series Type 1 = PCB - 3.5 mm pinning, flat 3 = PCB/Plug-in - 3.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Technical data Insulation according to EN 61810-1 1 pole Nominal voltage of supply system V AC 230/400 Rated insulation voltage V AC 250 Pollution degree 3 A 2 pole 230/400 400 250 400 2 3 2 Insulation between coil and contact set Type of insulation Reinforced (8 mm) Reinforced (8 mm) III III kV (1.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Contact specification F 40.1 - Electrical life (AC) v contact current Types 40.31/51/61 (page 3) F 40.2 - Electrical life (AC) v contact current Type 40.52 (page 3) Limit for 40.31/51 F 40.3 - Electrical life (AC) v contact current Types 40.31/51/61 (page 4) Cycles Cycles Resistive load - cosϕ = 1 Inductive load AC15 Resistive load - cosϕ = 1 Inductive load AC15 F 40.4 - Electrical life (AC) v contact current Type 40.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Contact specification H 40.1 - Maximum DC1 breaking capacity Types 40.31/51/52/61 (page 3) H 40.2 - Maximum DC1 breaking capacity Types 40.31/51/52/61 (page 4) and 40.11 (page 5) 40.61 current limit 40.11/31/51 current limit 40.52 current limit 40.52 - 2 contacts in series single contact DC voltage (V) DC breaking current (A) DC breaking current (A) 40.61 current limit 40.31/51 current limit 40.52 current limit A 40.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Coil specifications DC coil data - 0.5 W sensitive (types 40.31/51/52/61/62) Nominal Coil Operating range Resistance Rated coil voltage code consumption Umin Umax R I at UN UN V V V mA Ω 5 7.005 3.7 7.5 50 100 6 7.006 4.4 9 75 80 7 7.007 5.1 10.5 100 70 9 7.009 6.6 13.5 160 56 12 7.012 8.8 18 288 42 14 7.014 10.2 21 400 35 18 7.018 13.2 27 650 27.7 21 7.021 15.4 31.5 900 23.4 24 7.024 17.5 36 1150 21 28 7.028 20.5 42 1600 17.5 36 7.036 26.
40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A 40 SERIES Contact specification R 40 - DC coil operating range v ambient temperature Standard coil R 40 - DC coil operating range v ambient temperature Sensitive coil, types 40.31/51/52/61/62 A 40.61 40.31/51/52/62 R 40 - DC coil operating range v ambient temperature Sensitive coil, type 40.11 R 40 - AC coil operating range v ambient temperature 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max.
40 SERIES 40 SERIES PCB/Plug-in relays 8 - 10 - 12 - 16 A Outline drawings Types 40.31/51/52/61/62 (page 3 e 4) Types 40.31/51/52/61 (page 4) Type 40.11 (page 5) A VI-2018, www.findernet.com * (3.5 or 5.
95 SERIES Socket overview for 40 series relays 40 SERIES Module Socket Relay Description Mounting Accessories 99.02 95.P3 40.31 40.51 40.52 40.61 40.62 Panel or 35 mm rail (EN 60715) mount --Coil indication and EMC 95.P5 Push-in terminal sockets --For fast cable connection --Top terminals - Contacts --Bottom terminals - Coil 95.P5 See page 14 Relay Description 99.02 95.03 40.31 95.05 40.51 40.52 40.61 40.
40 SERIES 95 SERIES Socket and accessories for 40 series relays A 95.P5 Approvals (according to type): 095.91.3 060.48 Push-in terminals socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 8-way jumper link 2-way jumper link (12.5 mm pitch) 2-way jumper link (4.6 mm pitch) Marker tag holder (for tags 060.
95 SERIES Socket and accessories for 40 series relays 2-way jumper link for 95.P3 and 95.P5 sockets Rated values 40 SERIES 097.42 10 A - 250 V A 097.42 Marker tag holder for 95.P3 and 95.P5 sockets 097.00 86 series timer modules (12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) (110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h) (230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000 86.30.8.120.0000 86.30.8.240.0000 097.00 86.30 99.02 Approvals (according to type): 99.
95 SERIES Socket and accessories for 40 series relays 40 SERIES A 95.05 Approvals (according to type): ertain relay/socket C combinations 095.01 Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 8-way jumper link Marker tag holder (for tags 060.
95 SERIES Socket and accessories for 40 series relays 95.55 Approvals (according to type): 095.91.3 Screwless terminal socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) Modules (see table below) Timer modules (see table below) Sheet of marker tags for plastic retaining and release clip 095.91.
40 SERIES 95 SERIES Socket and accessories for 40 series relays Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 8-way jumper link Identification tag Modules (see table below) Marker tag holder Sheet of marker tags for plastic retaining and release clip 095.91.
95 SERIES Socket and accessories for 40 series relays 40 SERIES Screw (Box clamp) terminal socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip Plastic retaining and release clip (supplied with socket - packaging code SPA) 8-way jumper link Identification tag Modules (see table below) Sheet of marker tags for plastic retaining and release clip 095.91.3 and for marker tag holder 097.
40 SERIES 95 SERIES Socket and accessories for 40 series relays Screw terminal (Box clamp) socket panel or 35 mm rail mount For relay type Accessories Metal retaining clip 8-way jumper link Modules (see table below) Technical data Rated values Dielectric strength (between coil and contacts) Protection category Ambient temperature °C A 95.63 Approvals (according to type): Screw torque Wire strip length Max. wire size for 95.63 and 95.65 sockets 95.65 Approvals (according to type): 95.63 40.31 95.
95 SERIES Socket and accessories for 40 series relays Approvals (according to type): 95.13.2 (blue) 95.13.20 (black) 95.15.2 (blue) 95.15.20 (black) 40.31 40.51, 40.52, 40.61, 40.62 A 095.51 095.52 12 A - 250 V 10 A - 250 V* 6 kV (1.2/50 µs) between coil and contacts IP 20 °C –40…+70 * For currents > 10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). With the relay 40.51 the change-over contact will be 21-12-14. 40.