Data Sheet

A
Technical data
Insulation according to EN61810-1
1 pole 2 pole
Nominal voltage of supply system VAC 230/400 230/400
Rated insulation voltage VAC 250 400 250 400
Pollution degree 3 2 3 2
Insulation between coil and contact set
Type of insulation Reinforced (8mm) Reinforced (8mm)
Overvoltage category III III
Rated impulse voltage kV (1.2/50µs) 6 6
Dielectric strength VAC 4000 4000
Insulation between adjacent contacts
Type of insulation Basic
Overvoltage category II
Rated impulse voltage kV (1.2/50µs) 2.5; 4 (40.52 page 3 and 40.62)
Dielectric strength VAC 2000; 2500 (40.52 page 3 and 40.62)
Insulation between open contacts
Type of disconnection Micro-disconnection Micro-disconnection
Dielectric strength V AC/kV (1.2/50µs) 1000/1.5 1000/1.5
Insulation between coil terminals
Rated impulse voltage (surge) differential mode
(according to EN 61000-4-5) kV(1.2/50µs) 2
Other data
Bounce time: NO/NC ms 2/5
Vibration resistance (10…150)Hz: NO/NC g 20/5 (1 changeover) 14/2 (2 changeover)
Shock resistance NO/NC g 20/13 (1 changeover) 20/12 (2 changeover)
Power lost to the environment without contact current W 0.65
with rated current W 1.2 (40.11/31/51) 2 (40.61/52/62)
Recommended distance between relays mounted on PCB mm ≥5
7
VI-2018, www.findernet.com
40
SERIES
40 SERIES
PCB/Plug-in relays 8 - 10 - 12 - 16A