User's Manual
- 6 -
otherwise the outdoor sensor learning mode will be terminated right after the touch of LCD. When outdoor
transmitter has been registered, the Touch Screen Weather Station will automatically switch to the normal
display mode from which all further settings can be performed by the user.
If no RCC signal is detected in the initial setup, the transmitter will try once every hour to get an RCC signal
until a signal is received. Once the transmitter receives the RCC signal it will transmit the signal to the monitor.
On the monitor the RCC icon will be displayed, if the monitor doesn’t receive the RCC signal or loses the
signal the RCC icon will not be display.
Note: The best condition for reception is at night, between midnight and 6:00am – when there is less
atmospheric interference.
Positioning
Once you have verified that all of the components of the weather station are working, they can be positioned
in their permanent places. Before permanently mounting, make sure that all components work properly
together at their chosen mounting or standing locations. If e.g. there appear to be problems with the 868 MHz
radio transmission, they can mostly be overcome by moving the mounting locations.
Note:
Commonly the radio communication between receiver and transmitter in the open field can reach a
distance of up to 330 feet providing that there are no interfering obstacles such as buildings, trees,
vehicles, high voltage lines, etc.
Radio interferences such as PC screens, radios or TV sets can, in bad cases, entirely cut off radio
communication. Please take this into consideration when choosing standing or mounting locations.
Setting Up
Note:
Because of the default settings already determined by the manufacturer it may not be necessary for the
majority of users to perform – except the Relative Air Pressure (see further down) - any further basic
settings. Changes, however, can be easily made.
For basic settings, the following menu is started by touching the Touch Screen in the desired display area.
The basic settings can now be performed in the following successive order:
Note: setting procedure can be exited at any time by touching any other function area (except
“+”, “-” or “ON/OFF”).
indoor temperature
Activate the indoor temperature related setting by
1)Touch the INDOOR TEMPERATURE section, + button and – button will be flashing. Touch the
+ button or – button to Shift the display unit between ℃ and ℉
2)Touch the INDOOR TEMPERATURE section again to set the indoor temperature high alarm
function, the +, ON/OFF and – button will be flashing, HI AL icon will light up. Touch the+ button