User's Manual

- 8 -
develop an average for how far off the readings are.
Do not compare rainfall readings to reading obtained from television, radio, newspapers, or neighbors’
readings. Such readings are not located in your specific environment and therefore are not an accurate
measurement of the weather readings taking place in your surroundings. The rain collector is carefully
tested at the factory to conform to the specifications listed in the back of this manual.
The history rainfall calibration factor is applied to the running total, not individual tips. All of the rainfall
figures are calculated from the total number of tips recorded by the station since it was reset. The total is
multiplied by 0.3 to get a total in mm. This is then converted to inches if necessary by multiplying by
0.0393700787. The calibration multiplier is then applied to this, and this is the figure that remembers and
compares each time a new total is read from the station.
History Modes
- While in Normal Mode, press the HISTORY key to enter the History Mode.
- In the history mode, press SET key will trigger the history clear procedure: the word of “CLEAR” will
be flashing, hold the SET key for 2 seconds will clear all the history records.
- In the history mode, press the MIN/MAX key to select the record over the past 24hours at increments
of -3 hours, -6 hours, -9 hours, -12 hours, -15 hours, -18 hours, -21 hours, -24 hours.
Press the HISTORY key or key idle 30 second to return to Normal Mode
Alarm Modes
- While in Normal Mode press the ALARM key to enter the High Alarm Mode, Press the ALARM key
again to enter Low Alarm mode, press the ALARM key the third time to return the Normal Mode.
Remark: after the initial pressing of ALARM key, the display will be refreshed to show current high, low
alarm values. Normal alarm value will be displayed only for those already activated, all other not
activated values will be displayed with “- - -“or “- -“instead.
-In the High Alarm Mode press the SET key to select the following alarm modes:
1. Time alarm
2. Wind speed high alarm (0-50m/s)
3. Gust speed high alarm (0-50m/s)
4. Wind direction alarm
5. 1Hour rain high alarm (0-999.9mm)
6. 24 hour rain high alarm (0-999.9mm)
7. Outdoor humidity high alarm (1%-99%)
8. Outdoor temperature high alarm (
-40˚C--60˚C)
9. Wind chill high alarm (
-40˚C--60˚C)
10. Dew point high alarm (
-40˚C--60˚C)
11. Indoor humidity high alarm (1%-99%)
12. Indoor temperature high alarm (
-9.9˚C--60˚C)
-In the Low Alarm Mode press the SET key to select the following alarm modes:
1. Time alarm
2. Outdoor humidity low alarm (1%-99%)
3. Outdoor temperature low alarm (
-40˚C--60˚C)
4. Wind chill low alarm (
-40˚C--60˚C)
5. Dew point low alarm (
-40˚C--60˚C)
6. Indoor humidity low alarm (1%-99%)
7. Indoor temperature low alarm (
-9.9˚C--60˚C)