User Manual

Version 1.0 Page 23
Figure 19
Figure 20 summarizes the set mode sequence and commands.
Command
Mode
Settings
TEMP. and
MAX/MIN
+ 5 seconds
Enter Calibration
Mode, Indoor
Temperature
Press [WIND +] or [PRESSURE -] to adjust the indoor
temperature up or down.
To restore to factory default, press [ALARM].
[SET]
Indoor Humidity
Press [WIND +] or [PRESSURE -] to adjust the indoor
humidity up or down.
To restore to factory default, press [ALARM].
[SET]
Outdoor Temperature
Press [WIND +] or [PRESSURE -] to adjust the outdoor
temperature up or down.
To restore to factory default, press [ALARM].
[SET]
Outdoor Humidity
Press [WIND +] or [PRESSURE -] to adjust the outdoor
humidity up or down.
To restore to factory default, press [ALARM].
[SET]
Absolute Pressure
Press [WIND +] or [PRESSURE -] to adjust the absolute
pressure up or down.
To restore to factory default, press [ALARM].
Note: The absolute pressure calibration affects the
relative pressure by the same amount. It is recommend
you calibrate the relative pressure only, per Section 6.3.
[SET]
Wind Direction
Press [WIND +] or [PRESSURE -] to adjust the wind
direction up or down.
To restore to factory default, press [ALARM].
[SET]
Wind Speed Factor
Press [WIND +] or [PRESSURE -] to adjust the wind
speed factor up or down.
To restore to factory default, press [ALARM].
[SET]
Rain Factor
Press [WIND +] or [PRESSURE -] to adjust the rain
factor up or down.
To restore to factory default, press [ALARM].
[SET]
Exit calibration mode
Figure 20
6.10.2 Calibration Ranges