FINETAGESL INSTALLATION MANUAL * Make sure you read „Cautions in Use‟ before using it. * The appearance and composition of the product may differ from the image.
Copyright ©FINETEKCo., Ltd. 2019 • The copyright of this installation belongs to©FINETEK. This manual cannot be copied or duplicated for personal user or purpose. • To deliver the latest, accurate information on this manual, FINETEK may change certain specifications, product composition and contents under FINETEK‟s decision without notification.
About This Manual. You are welcomed as a new customer of ©FINETEK. For proper use of the product you purchased, please understand this manual before use. It will help you operate the product if you frequently refer to this manual. This manual guides you to install and use the product. If any explanation is missing, the Windows screen may be captured for explanation. This manual is written for ordinary users and may not explain internal technical issues.
Cautions in Use Before using the product, make sure to read „Cautions in Use‟ for proper use. „Cautions in Use‟ deal with important materials regarding safety, so make sure you stick to them. When used wrong, it may be highly dangerous. There is danger of fire or electric shock for the following. Connect the product power cord only to the AC socket specified in the use manual or product manual. Do not spill water in the product nor expose the product to moisture.
Cautions in Use When used wrong, it may cause small damages. • When the product is stained, use soft cloth or towel to wipe. Never use chemical solution (thinner, solvent, etc.) for wiping. • Never use or leave the product in the following places - A place too cold or hot - A place with high moisture or dramatic temperature change - Dusty place • Do not place a magnetic object around this product. • Static electricity may damage the internal parts of this product.
Chapter I Product Composition
FINETAG ESL INSTALLATION MANUAL I.PRODUCT COMPOSITION 1. System Composition • System flow chart -. POS: Market management server with product and price information -. ESL Manager: A server that receives data from POS and sends data to AP and checks operation status of AP and TAG -. Router :Path connecting server to distributed AP -. AP :The role of receiving and transmitting TAG and data over wireless communication by receiving data from ESL Manager server through TCP/IP. -.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL 2. System Operation Specifications Number of Tags managed per AP Maximum4,000 units Distance between APand Tag for communication Maximum 20m There may be variance depending on installation environment, network status and other conditions.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL 3. AP Specifications FNTAP Model LED Color Red INDICATOR Wireless Communication Power Green Ethernet link Amber Ethernet Activate Blue/Red Network Sign Operation Active(Blue) / Error(Red) Ethernet (10/100 Base) IEEE 802.15.4 Based on 2.4GHz ISM Band, Data Rate: 250Kbps, Service Area: Radius Max. 30m (Line of Sight) Antenna External Dipole Antenna, 3.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL Model Maximum Transmit Power AP 2.4GHz - 802.15.4 (Zigbee) 3.5 dBm (RF1), 2.5 dBm (RF2) 2.4GHz 20.0 dBm (100mW) Available Transmit 18.2 dBm (66mW) 16.4 dBm (44mW) Power Setting 14.2 dBm (27mW) 11.7 dBm (15mW) 09.2 dBm (9mW) Caution: Maximum transmission power setting complies with regulations for each channel or country.
FINETAG ESL INSTALLATION MANUAL I.PRODUCT COMPOSITION 4. TAG Specifications ①FNT16, FNT22 Model Display Wireless Communication FNT16 e-Paper 1.6" Matrix Data Rate: 250Kbps, Service Area : Radius Max. 30m (Line of Sight) 2.4GHz - 802.15.4 (Zigbee) Transmit Power 2 dBm Approval FCC, KC ROHS ROHS Compliance Power Coin Battery CR2450 x 1 Temperature Size Weight e-Paper 2.2" Matrix IEEE 802.15.4 Based on 2.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL ②FNT29 Model Display Wireless Communication FNT29 e-Paper 2.9" Matrix IEEE 802.15.4 Based on 2.4GHz ISM Band, Data Rate: 250Kbps, Service Area : Radius Max. 30m (Line of Sight) Maximum 2.4GHz - 802.15.4 (Zigbee) Transmit Power 0 dBm Approval TBD ROHS ROHS Compliance Power Coin Battery CR2450 x 2 Operating Temperature 0°C ~ 40°C / 41°F~104°F Size 84.9mm x 41.5mm x 12.4mm Weight 27.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL ③FNT42 Model Display Wireless Communication FNT42 e-Paper 4.2" Matrix IEEE 802.15.4 Based on 2.4GHz ISM Band, Data Rate: 250Kbps, Service Area : Radius Max. 30m (Line of Sight) Maximum 2.4GHz - 802.15.4 (Zigbee) Transmit Power 2 dBm Approval FCC, KC ROHS ROHS Compliance Power Coin Battery CR2450 x 3 Operating Temperature 0°C ~ 40°C / 41°F~104°F Size 95.8mm x 82.9mm x 13.2mm Weight 68.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL ④FNT58 Model Display Wireless Communication FNT58 e-Paper 5.8" Matrix IEEE 802.15.4 Based on 2.4GHz ISM Band, Data Rate: 250Kbps, Service Area : Radius Max. 30m (Line of Sight) Maximum 2.4GHz - 802.15.4 (Zigbee) Transmit Power -0.5 dBm Approval TBD ROHS ROHS Compliance Power Coin Battery CR2450 x 4 Operating Temperature 0°C ~ 40°C / 41°F~104°F Size 130.2mm x 105.4mm x 13.2mm Weight 124.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL ⑤FNT75 Model Display Wireless Communication FNT75 e-Paper 7.5" Matrix IEEE 802.15.4 Based on 2.4GHz ISM Band, Data Rate: 250Kbps, Service Area : Radius Max. 30m (Line of Sight) Maximum 2.4GHz - 802.15.4 (Zigbee) Transmit Power 2 dBm Approval TBD ROHS ROHS Compliance Power Coin Battery CR2450 x 4 Operating Temperature 0°C ~ 40°C / 41°F~104°F Size 117.1mm x 175mm x 13.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL ⑥Specifications Hardware / Software Version: Operating Temperature:5°C ~ 40°C / 41°F~104°F Distance :Radius Max. 30m (Line of Sight) Transmission :2.4GHz - 802.15.4 (Zigbee) Output Power : ( Unit : dBm ) MODEL Target Tolerance Max FNT22R 0 ±2 2 FNT29R -2 ±2 0 FNT42R 0 ±2 2 FNT58R -2.5 ±2 -0.5 FNT75R 0 ±2 2 AP RF1 1.50 ±2 3.50 AP RF2 0.50 ±2 2.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL 5. Remote Control Specifications Model Display Wireless Communication IDRM1A LED Display (Red : Click / Blue : Link) IEEE 802.15.4 Based on 2.4GHz ISM Band, Data Rate: 250Kbps, Service Area : Radius Max. 30m (Line of Sight) Maximum 2.4GHz - 802.15.
I.PRODUCT COMPOSITION FINETAG ESL INSTALLATION MANUAL 6. Product Kit Composition AP Product Display Power adaptor Access Point 5V/3A) (AP) RJ-45 ethernet cable (DC Exterior antenna Product Display(TAG – TAG 1.6inch – TAG 2.2 inch – TAG 2.9inch – TAG 4.2inch FNT16) Product Display(TAG FNT22) Product Display(TAG FNT29) Product Display(TAG FNT42) Remote Control (TAG – FNT58) TAG 5.
FINETAG ESL INSTALLATION MANUAL I.PRODUCT COMPOSITION Product Display(TAG – TAG 7.
Chapter II Installation
1. Software Installation 1.1 Recommended Specifications for Installation Computer Installation of FINETAG ESL requires the following computer specifications: Requirement Item Minimum Recommended Windows 7 SP164 or above Windows 10 64bit 64bit Memory 4GB or higher 8GB or higher Disk HDD 10GB or higher SSD 20GB or higher OS Processor Ethernet Intel Celeron 2.4 GHz Intel i7 or higher or higher 100M/1Gbps or higher 100M/1Gbps or higher 1.
IP must be granted to the computer to be installed. The latest version of Google Chrome browser must be installed on the computer. (Chrome, the latest version : v71.0.3578.
1.4 Software Installation 1. Check the installation file name. *The file name differs depending on the software version provided. 2. Launch the installation file and click on [Next]. 3. Check the installation items and click on [Next].
4. Check the destination folder and click on [Install]. 5. Confirm installation completion and click on [Finish]. 6. Find the icon below on the desktop.
1.5 Check Software Status. FINETAG ESL is automatically executed upon installation.Use Windows Services Manager to check if the software operates well. 1.5.1 How to Execute Windows Services Manager 1. PressWindows+R to execute Run. 2. Enter “services.msc” and click on [OK]. 1.5.2 ESL Server Check Check on Windows Services Manager to confirm“ESL Server”isRunning.
1.5.3 Check Nginx Web Server Check that “Ngnix” is Running on Windows Services Manager. 1.5.4 Check MariaDBDatabase Server Check that “MySQL” is Running on Windows Services Manager.
1.6 Computer Setting 1.6.1 Add on Windows Defender Firewall List 1. Type “firewall” in Windows start menu search bar. 2. Select [Windows Defender Firewall]. 3. Click on “Allow an app or feature through Windows Defender Firewall”.
4. Click on [Change settings] to activateappslist. 5. Click on [Allow another app].
6. Select C:\FINETEK\ESL Server\FEServer.exefile and click on [Open]. 7. Click on [Add].
8. Check that FEServer.exe file is added on the allowed apps and features list. Check both private and public. 9. Follow the same steps to add C:\nginx-1.14.0\nginx.exefile on the Firewall list.
10. Click on [OK] to close the window.
1.6.2 Power Mode Best Performance If the software is installed on a laptop, it is recommended to connect AC power and use “Best Performance” mode. Caution)The way to change to “Best Performance” mode may differ from a Windows OS version to another. 1.6.3 Dismiss Battery Save Mode If the software is installed on a laptopturn off battery save mode. Caution)The way to “dismiss battery save mode” may differ from a Windows OS version to another.
1.7 ESL Client Login 1. Double click theFINETAGESL icon on Desktop. 2. Enter email address and password on the log-in page and click on [login]. The default email address and password are presented below. email : admin@mystore.com password : admin_pass 3. Check the monitoring page is presented as below.
1.8 Delete Software If you decide to not use ESL Software any more, you may useProgram Uninstaller to uninstall the software. 1.8.1 How to Launch Program Uninstaller 1. Type “control” in Windows start menu search bar. 2. Select [Control Panel]. 3. Select [Uninstall a program]menu to openProgram and Features.
1.8.2 Uninstall MariaDBDatabase Server 1. Select “MariaDB 10.2 (x64)” and click on[Uninstall/Change]. 2. Click on [Next].
3. Select [Remove]. 4. Select [Remove data]. MariaDB may not be re-installed if you select “Keep data”.
5. Click on [Remove] to start uninstallation. 6. Select “Close the applications and attempt to restart them” and click on[OK].
7. Click on [Finish] once uninstallation is completed. 1.8.3 Uninstall NginxWeb Server 1. Select “Nginx” and click on [Uninstall].
2. Click on [Next]. 3. Check the uninstallation path and click on [Uninstall].
4. Click on [Finish] after uninstallation is completed. 1.8.4 ESL Server Uninstall 1. Select “ESL Server” and click on[Uninstall].
2. Click on [Next]. 3. Check items to be deleted and click on [Next].
4. Check the uninstallation path and click on [Uninstall]. 5. Click on [Finish] after uninstallation is completed.
2. AP Installation and Registration 2.1 Select AP Location To maintain AP performance at its best, consider the following select the location. Do not install nearby industrial equipment including transformer, microwave, refrigerator, etc.(keep apart more than 5m) Metal, concrete, wall, etc. blocks communication so signals may be lost. The ideal installation height is 3m(10ft.) from the ground. Have the antenna face the ceiling to improve reception. Place AP as close to Tag as possible.
2.2 APInstallation ① Ceiling Installation When installing at ceiling, place in open place rather than in closed space, and keep 3m or more away from the ground if possible.Also, organize the cables to not interrupt passengers Check if the antenna is installed at AP. Antenna Port Place AP in the space Tagis installed so everyone can see it well. Connect the cable if installation is completed.
In case you do not use the Wall Bracket, get rid of the TOP case of theAP and use the hole on the bottom to fix on a wall. Fix the AP and place the TOP case.
2.3 APCable Connection ① Ethernet Cable Connection Use an ethernet cable to connect the router and AP. Power Jack Ethernet Cable ② Power Cable Connection When using power adaptor to supply power, use the provided adaptor to connect to the power port. You may use a DC adaptor or a PoE injector for AP power.If it is not easy to use AC power where AP is to be installed, you may use aPoEinjector or PoE switch hub to supply power only with an ethernet cable.
Data Power PoE Injector Connect to LAN port The following is how to connect PoEinjector with the AP. ① Connect the injector power code to the AC socket. ② You can find Data In(LAN) portand Data Out(POE) port on the injector. ③ Use an ethernet cable to connect the router to Data In(LAN). ④ Connect Data Out(PoE) port to AP.
2.4 APFunction Check You can check the AP status from the 4 LED‟s on the front side. Red LED LED is turned on when power is supplied. Green LED LED is turned on when connected to network. Yellow LED LEDflickers on when communicating with network. Blue LED / Red LED Blue LED flickers when AP normally works. Red LED flickers when an error occurs.
2.5 AP Registration Log in to ESL client and move toAP Management page. AP must be connected to the router. Without additional setting, the AP is voluntarily allocated with an IP via the DHCP of the router. ① Enter the startIPand finishIP. ② Click on [AP Discovery] to search AP. ③ Check the Status is online after AP is found.
3. TAGInstallation and Registration Consider the following when installing TAG. Do not install nearby industrial equipment including transformer, microwave, refrigerator, etc. (keep apart more than 5m) Metal, concrete, wall, etc. blocks communication so signals may be lost. If the battery is separately delivered without being installed, make sure batteries are not in contact with each other. (A fire may break out due to damage of the battery or high temperature.) Fix the TAG so it does not fall off.
③ Tag Management page after Log in to ESL Client and then move to Tag Management page. Find the TAG with Serial Number“0007FD8832D”. You will find no change on the screen if the APorESLServer is not under operation.In this case, check the status of AP and ifESLServer is being launched. The battery is consumed fast when the server or AP connection is lost, so keep the it connected.
4. Remote Control Usage The remote control is used for tag reset and shut down. The tag is reset when the bottom right of the tag and the upper part of the remotecontrol backside is in touch. The tag flickers several times and displays the price and barcode display received from AP. (붉은 색으로 표기된 부분을 서로 터치) Contact the remote control to the tag and press the remote control button every second.
FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.