We Make Things Easy DOOR LOCK T IM ER Installer Guide
DOOR LOCK T IM ER AdapTec is a combination of a power supply and a door controller packaged in a compact box to ease on installation, to provide power supply and to enhance access control functionalities. FUNCTIONS • To power on the time attendance system of FingerTec® terminals. • To link door accessories including EM Lock and Drop Bolt with the FingerTec® terminals. • To control In-Out reader system; a system where two terminals control one entrance.
THE DESIGN AdapTec consists of 2 main modules and a timer: 3 1 2 3 1 Power supply/power input module. Access control/power output module. Door lock timer. 2 POWER SUPPLY/POWER INPUT MODULE 1 1 This portion is to be connected to power source with AC110~240V. AC current will be supplied into this side and a DC 12V 3A current will be generated as output. 2 These two cables, -V and +V are default and connected to the inner part of AdapTec. Please do not remove or change these cables.
WIRING DIAGRAMS AC900 TIME ATTENDANCE ONLY STEP 1 • Connection Points Access Control/Power Output Module Siren Accept 0 Relay 12V OK 0 EM 12V Siren Accept MAX 0.5A 0 12V AdapTec AC Output Voltage Tamper Switch Input EXT.
WIRING DIAGRAMS AC900 ACCESS CONTROL ONLY OR TIME ATTENDANCE & DOOR ACCESS STEP 1 • Connection Points Access Control/Power Output Module Siren Accept 0 Relay 12V OK 0 EM + Lock - EM 12V AdapTec AC Siren Accept MAX 0.5A 0 12V Output Voltage Tamper Switch Input EXT.
WIRING DIAGRAMS R2/M2, i-Kiosk100, i-Kiosk100 Plus, Q2i and Kadex TIME ATTENDANCE ONLY STEP 1 • Connection Points Access Control/Power Output Module Siren Accept 0 Relay 12V OK 0 EM 12V AdapTec AC Siren Accept MAX 0.5A 0 12V Output Voltage Tamper Switch Input EXT.
WIRING DIAGRAMS R2/M2, i-Kiosk100, i-Kiosk100 Plus, Q2i and Kadex ACCESS CONTROL ONLY OR TIME ATTENDANCE & DOOR ACCESS STEP 1 • Connection Points Access Control/Power Output Module Siren Accept 0 Relay 12V OK EM 12V 0 EM + Lock - Emergency 2 Break Glass (NC) 3 AdapTec AC Siren Accept MAX 0.5A 0 12V EXT.
WIRING DIAGRAMS Face ID 2 ACCESS CONTROL ONLY OR TIME ATTENDANCE & DOOR ACCESS STEP 1 • Connection points Access Control/Power Output Module Siren Accept 0 Relay 12V OK EM 12V 0 EM + Lock - AdapTec AC Siren Accept MAX 0.5A 0 12V Output Voltage Tamper Switch Input EXT.
WIRING DIAGRAMS Face ID 2 TIME ATTENDANCE ONLY STEP 1 • Connection points Access Control/Power Output Module Siren Accept 0 Relay 12V OK EM 12V 0 AdapTec AC Siren Accept MAX 0.5A 0 12V Output Voltage Tamper Switch Input EXT.
AN ALARM SIREN TO SECURE YOUR FINGERTEC® TERMINAL For all FingerTec® door access control models, there is a security spring behind the terminal. During normal operation, the security spring is compressed and once the reader is dismantled, the spring will be released and “System broken” message will appear onscreen. During the release of the spring, the reader is outputting alarm signal. Nonetheless, no alarm sound is emitted because the reader is not equipped with preinstalled siren.
FUNCTION • AC900 For AC900, you will need to connect AC900, alarm siren and AdapTec AC as below. Access Control/Power Output Module Siren Accept 0 0 EM 12V Siren Output MAX 0.6A 0 12 Output Tamper EXT.
INSTALLATION • Wooden Door 1 WOODEN DOOR WALL WALL 1 2 Back Steel Plate 2 Tighten the 4 screws to fix the Back Plate on the wall. Screws 4 feet / 1.2 meter (recommended) 3 3 Install the keyswitch as per instructions given in the box. The keyswitch is an override key in case of system failure or breakdown. OUTDOOR 2 1 To install FingerTec® AC900/M2/R2 on a wall, drill 5 holes as shown. 4 small holes are for the screws and the bigger hole is for the network cable.
4 1 12V 3A DC Power Out- 2 2 put AC110/240V Power Input 33 1 Note: Refer to AdapTec user guide for wiring diagrams. 1 Computer/ Network Hub/ Network Switch To FingerTec®Series 2 AdapTec AC ABOVE CEILING 3 12V Rechargeable Battery CEILING BELOW CEILING Note: It is recommended to place 1 , 2 and 3 out of sight, either above a ceiling or wall-mounted. 5 CEILING Emergency Break Glass Emergency Break Glass Push Button 4 feet / 1.2 meter (recommended) and Push Button should be installed indoor.
INSTALLATION • Glass Door 1 GLASS DOOR WALL WALL 1 2 2 Tighten the 4 screws to fix the Back Plate on the wall. Back Steel Plate Screws 4 feet / 1.2 meter (recommended) 3 Install the keyswitch as per instructions given in the box. The keyswitch is an override key in case of system failure or breakdown. 3 OUTDOOR 2 1 To install FingerTec® model on the wall, drill 5 holes as shown. 4 small holes are for the screws and the bigger hole is for the network cable.
4 1 12V 3A DC Power Out- 2 2 put AC110/240V Power Input 33 1 1 Computer/ Network Hub/ Network Switch To FingerTec®Series ABOVE CEILING 2 AdapTec AC Note: Refer to AdapTec user guide for wiring diagrams. 3 12V Rechargeable Battery CEILING BELOW CEILING Note: It is recommended to place 1 , 2 and 3 out of sight, either above a ceiling or wall-mounted. 5 CEILING Emergency Break Glass and Push Button should Emergency Break Glass be installed indoor.
INSTALLATION How to mount an AdapTec AC onto a wall 1 Remove the L-shape piece from the AdapTec AC Find an L-shape piece at the top right of an AdapTec AC. This piece is attached to the AdapTec AC by 2 screws. 2 Install the piece to the AdapTec AC Attach the L-shape to the AdapTec AC as shown and tighten the screws. 4 After removing the piece, you will have one L-shape piece and 2 screws.