Actions for Capture Filters
Table 7-4 shows actions available for capture filters:
An example
Filter Actions dialog box for capture filters is shown below:
Figure 7-3. Example Filter Actions Dialog Box
The state number and the line number of the statement within the state are given in
the title bar of the dialog box.
Table 7-4. Capture Filter Actions
Action Description
Capture Capture the frame.
Trigger Capture the frame. Continue capture and fill the buffer to the percent-
age specified by the user in the After trigger, continue to capture
packets until the buffer is: %% full field.
Increment Custom
Counter
Increment the custom counter. For THGm, any combination of seven
counters can be incremented.
Change Filter Operation Go to a different filter state for processing the next incoming packet.
The state can be the current state or any other state defined in the