Surveyor User's Guide

9-15
Alarms
Alarm Examples
9
Alarm Examples
The following are six examples for alarms and alarm groupings. Each provides a
picture of the
Current Module Alarms dialog box and a description of what will
occur when for the alarms are triggered.
Alarm Example, Utilization
Figure 9-6. Alarm Example, Utilization
This simple example shows an alarm group consisting of one MAC Layer alarm for
Utilization. This alarm samples network traffic at five-second intervals. When the
absolute, rising value of 50 (percent utilization) is exceeded, Surveyor issues an
audible alarm and displays a message in Surveyor’s message window.