Surveyor User's Guide

10-122
Surveyor
User’s Guide
Hints and Tips for Expert Features
Double-click any symptom in a table to view Diagnostic information.
When looking at Expert View in Monitor only mode, Frame IDs are displayed
for information only and you cannot examine a frame related to a symptom. If
you need to look at specific frames related to Expert Symptoms, look at the
frame information in the capture buffer or in a capture file.
Expert Views can be disabled on a per module basis. Select
Module Set-
tings… from the Configuration menu and choose the Modes Tab. Remove the
check from the
Expert Views box.
Click, hold, and drag a column border to resize columns in any Expert View
Table. Increasing the size of the
Symptom column gives you a view of the com-
plete name of the symptom.
Click, hold, and drag a column border to remove columns in any Expert View
Table. Double-click on the same column border to bring back the display of a
column.
Duplicate addresses appear both in the Duplicate Network Address Table and as
a symptom in Expert View.
Thresholds can be set for Expert Symptoms. Select
Expert Settings… from the
Configuration menu and find the symptom you want to change. Some threshold
values for symptoms cannot be changed.
Expert Symptoms can be selectively disabled. Select
Expert Settings… from the
Configuration menu and find the symptom you want to disable from the tree
structure. Remove the check from the symptom. Some symptoms cannot be dis-
abled.
Expert Symptoms can be displayed in the Summary field of Capture View.
From the Configuration menu, select
Capture View Options Display and
select the
Display Expert Symptom check box. Packets that trigger an expert
symptom and have expert symptom information will display in reverse video.