AC6/6H & AC8/8H Horizontal Metric Models ASSEMBLY, INSTALLATION AND OPERATION MANUAL Part No.
TABLE OF CONTENTS Description Page Number Model/Serial Number.................................................................................................. 4 Important Notice......................................................................................................... 4 Chemical Reaction Disclaimer..................................................................................... 4 Safety Precautions..........................................................................................
Model Number and Serial Number Record the model number and serial number below for future reference. This is important information when ordering replacement parts or when technical assistance is required. The numbers are found on a label located on the motor adapter.
Safety Precautions for ATEX Pumps CAUTION: Proper o-ring material must be chosen for the fluid being pumped. Improper material selection could lead to swelling and be a possible source of leaks. This is the responsibility of the end user. WARNING: The pump must be checked for leaks on a regular basis. If leaks are noticed, the pump must be repaired or replaced immediately. WARNING: The pump must be cleaned on a regular basis to avoid dust buildup greater than 5 mm.
AC6 & 8 Assembly, Installation and Operation Unpacking and Inspection • Unpack the pump and examine for any signs of shipping damage. • If damage is detected, save the packaging and notify the carrier immediately. Section I - Assembly Tools Required: Metric box wrench set & metric deep well socket set - Pumps with Motors 1. No assembly required. Unpack the pump and motor and examine for any signs of shipping damage. If damage is detected, save the packaging and notify the carrier immediately. 2.
Section II - Installation Pump motor base should be securely fastened to a solid foundation. CAUTION: The NPSH available to the pump must be greater than the NPSH required. NPSH available should be two feet (.6 meters) greater than NPSH required. • Install the pump as close to the suction source as possible. • Support the piping independently near the pump to eliminate any strain on the pump casing. In addition, the piping should be aligned to avoid placing stress on the pump casing.
Flush Systems CAUTION: Some fluids react with water; use compatible flushing fluid. 1. Turn off the pump. 2. Completely close the suction and discharge valves 3. Connect flushing fluid supply to flush inlet valve. 4. Connect flushing fluid drain to flush drain valve. 5. Open flushing inlet and outlet valves. Flush system until the pump is clean.
Reassembly 1. Lubricate the rubber portion of the new stationary seal (item 5) with P-80 (or equivalent) or use soapy water. Do not use petroleum products to lubricate the rubber. Note: Keep the polished surface of the seal face clean. Use a piece of cardboard to protect the seal while pressing against the stationary face. 2. Press the stationary seal into the seal seat of the back head assembly so that the seal surface points away from the motor face. Place the back head into the motor adapter. 3.
AC6/AC6H Exploded View AC6-AC6H Spare Parts Item 1 2 3 4 5 6 7 8 9 10 11 12 13 AC6-AC6H Spare Parts - cont. Description Impeller Housing AC6SJS - 1-1/2" x 1-1/4" FBSP AC6SJS - 2" X 1-1/2" FBSP AC6HJS - 1-1/4" x 3/4" FBSP AC6SJS - 1-1/2" x 1-1/4" FNPT AC6SJS - 2" X 1-1/2" FNPT AC6HJS - 1-1/4" x 3/4" FNPT V Clamp 304 stainless steel Housing O-Ring FKM EPDM PTFE encapsulated silicone Impeller 316 Stainless Steel 5.25" Standard w/ IEC 90 B5 (AC6) 5.75" Standard w/ IEC 90 B5 (AC6) 6.
AC8/AC8H Exploded View AC8-AC8H Spare Parts AC8-AC8H Spare Parts Item 1 3 4 5 6 7 Description Impeller Housing AC8HJS - 1-1/4" x 3/4" FBSP AC8SJS - 2" x 1-1/2" FBSP AC8SJS - 2-1/2" x 2" FBSP AC8HJS - 1-1/4" x 3/4" FNPT AC8SJS - 2" x 1-1/2" FNPT AC8SJS - 2-1/2" x 2" FNPT Housing O-Ring FKM EPDM PTFE encapsulated silicone Impeller 316 Stainless Steel 6.25" High Head (AC8H) 7.00" High Head (AC8H) 8.00" High Head (AC8H) 6.50" Standard (AC8 IEC 100/112 B5) 7.00" Standard (AC8 IEC 100/112 B5) 7.
Section V - Troubleshooting General Notes: • Contact our Technical Service Department If you have any questions regarding product operation or repair: Phone: 1-800-888-3743 E-mail: techservice@finishthompson.com.