User's Manual

UM-0101-01.09 November 2009
7
Automatic Gain Control (AGC)
Automatic Gain Control circuitry is intended to keep repeater’s output power at a fixed level
when input signals exceed maximum values, avoiding quality signal degradation by
intermodulation generation.
When AGC is active AGC UL and/or AGC DL leds will be ON, this means that signal level from
donor and/or service area site, plus repeater gain produces an output power that is above the
maximum composite output power of the repeater. This should not be considered an undesired
working condition, far from that; this is the best operating condition because you are getting the
maximum composite output power available from the repeater.
Anyway is a good practice to increase attenuation (reducing gain), until AGC led turns off, this
operation releases AGC circuitry dynamic range.
Also is a good practice to check signals from donor site to ensure that undesired signals are not
being amplified by the repeater, or even desired signal levels are not excessively high taking
repeater to an overload condition.
Overload Protection
When AGC circuit reaches its limit, the power amplifier stage is shut down to prevent harmful
distortion and potential damage to the repeater. After approximately ten seconds the system
checks if overload condition is still present, if this happens, amplifiers will remain off. This cyclic
check will continue until condition that makes AGC circuitry reach its limits disappears.
Conditions that can cause AGC to reach its limits include the presence of one or more very
strong channels, a strong in-band noise source, or amplifier oscillation due to poor antenna
isolation.
Downlink Signal Indicator
Summarizes downlink repeater output. Indicates bad, poor, good, very good and excellent signal
levels as follows:
Bad RSSI, all leds off
Poor RSSI, first led ON
Good RSSI, first and second leds ON
Very Good RSSI, first, second and third leds ON
Excellent RSSI, all leds ON
Laboratory Measurements
For specific parameters verification and laboratory tests, please contact factory.
Detailed procedures, recommended tests set up, and a knowledge engineering team will bring
adequate support to perform this measurements in a comfortable and safely way.