User's Manual

UM-0840 21
4. If the Remote Unit has the NFPA Option, there is a dedicated cable gland for this purpose. A multi-
conductor cable can be used to connect the NFPA dry contacts to the Fire Department Control Box.
Figure 11; NFPA Dry Contact connection configuration
Figure 12; NFPA Dry Contact connection location inside the cabinet
5. Once the unit has been connected to the power source, it takes about 30 seconds to run a booting
routine. After that time unit is ready to be connected via USB cable to the Digital Master to a computer
running Fiplex Control Software (FCS) in order to be properly configured.
4 5 61 2 3
NC NO NC NO
Repeater
Fail
VSWR
Status of contacts (Alarms Off)
Pin 1 2 = VSWR (normally closed contact)
Pin 2 3 = VSWR (normally open contact)
Pin 4 5 = Repeater Fail (normally closed contact)
Pin 5 6 = Repeater Fail (normally open contact)