User's Manual

UM-0821 30
10. Once Signal Booster is configured, user can disconnect software using connection
button, now labelled “Disconnect”. Initial window will be shown.
If Signal Booster is disconnected or turned off, while Fiplex Control Software is connected
to device, software will go back to initial window. Moreover, if some communication
problem occurs while device is monitored, the software will go back to initial state as well.
3. Remote Web Server option
3.1. IP Connection
Fiplex Signal Boosters use an Ethernet module and 3G Router to give TCP/IP connectivity
(webserver and SNMP Agent). In local mode, user can connect directly a computer to the
Ethernet module using the inside Ethernet cable.
In order to access to web browser, default IP addresses of Ethernet module are detailed in the
next table:
IP Address
192.168.1.10
Network submask
255.255.255.0
Gateway
192.168.1.2
Computer network adapter configuration needs to be set to same network submask and gateway.
IP address can take any value in this IP range (192.168.1.11, for instance). These addresses can
be changed by user.
3.2. Web pages description