User's Manual

UM-0915 7
3. Ports
4. Commissioning
1. Connect RF IN and RF OUT. N type female connectors are used in the Signal Amplifier.
2. Once RF ports of the Signal Amplifier are properly loaded connect the DC port. Electrical installation
must provide differential and termo-magnetic breaker elements according to electric safety international
regulations.
3. Signal Amplifier chassis must be properly DC grounded.
4. Turn ON DC power.
5. Once the Signal Amplifier has been powered, it takes about 20 seconds to run a booting routine. After that
time Signal Amplifier is ready to be connected via USB cable to a computer running FCS Software in order
to be properly configured. See Part 2 Software of this manual to install FCS.
5. Starting Operation
BE SURE THAT BOTH RF PORTS ARE PROPERLY LOADED EITHER WITH
50 OHMS DUMMY LOADS, OR RADIATING SYSTEMS.
1. Turn on the Signal Amplifier, connect computer to Signal Amplifier through USB cable, and run Fiplex
Control Software.
2. Setup desired channel frequency. Since Signal Amplifier is a single channel device, user has to know
what frequency is used in Base Station or Transmitter.