Manual

AUDIO•COMMAND•CENTER•25/50 Operating Instructions
Document 51947 Rev. B ECN 03-763 11/14/03
Refer to the AUDIO•COMMAND•CENTER•25/50
Technical Manual P/N 51889 for more details.
Local Service Representative
Name:______________________________
Address:____________________________
Telephone:__________________________
Frame and mount adjacent to the control panel.
NORMAL - Only the green POWER ON LED is on. All other
LEDs are off.
PANEL - The key to open the panel can be found at this
location:_____________________________________
WHEN AUDIBLE DEVICES ARE SOUNDING -
FOR AN ALARM:
Evacuate the protected area.
Notify the monitoring service and/or the Fire Department
immediately. Tell them briefly what happened and what your
current status is.
If the Fire Department is responding, be prepared to provide
directions to arriving firefighters.
FOR TROUBLE ONLY:
Notify the monitoring service and/or Fire Department if the
host panel is connected to either one, and tell them what is
happening.
Silence local piezo by pressing the TROUBLE SILENCE key.
The yellow SYSTEM TROUBLE LED will remain on. Contact
authorized service personnel immediately!
TO PAGE IN STANDBY or ALARM
Press the ALL-CALL switch (if programmed for ALL-CALL)
or Zone 1 and/or Zone 2 switch. This will override the
evacuation tone/message if panel is in alarm
Key the microphone by pressing switch on side of microphone.
Speak clearly into microphone.
Release microphone switch and press the ALL-CALL switch
(or Zone 1 and/or Zone 2 switch) to continue evacuation tone/
message.
POWER FAILURE OR BROWNOUT - The AC power LED,
located on the main circuit board, will go out for AC fail or brownout.
SYSTEM TROUBLE LED and the local piezo will turn on for either
condition. Contact authorized service personnel immediately.
(Refer to Local Service Representative block below).
WARNING!
Do not allow trouble conditions to remain logged
in the system. Protection that the system offers
has been compromised, or eliminated when a
trouble condition exists.
1)
2)
1)
2)
3)
4)
1)
2)
3)
Manual Message Control:
• Press the desired message switch.
INSTRUCTIONS
SINGLE ZONE OPERATION
Paging:
ALL-CALL - press the ALL-CALL
Switch and then the microphone
Push-to-Talk switch.
Trouble Silence:
• Press to turn off the local trouble sounder.
Manual Message Control:
• Press the Zone 1 and/or Zone 2 switch and
then the message switch.
Paging:
• Press the Zone 1 and/or Zone 2
switch and then the microphone
Push-to-Talk switch.
Trouble Silence:
• Press to turn off the local trouble sounder.
DUAL ZONE OPERATION

Summary of content (1 pages)