User Manual Single Searing Station
10
The control panel MUST remain removable for servicing (see
PARTS LIST).
EXHAUST REMOVAL
If the unit is installed under an overhead structure, it must be
constructed of non-combustible material. An exhaust hood is
recommended. See below.
When using an exhaust hood:
The cooking grid area must be covered by an exhaust hood (with
a vent) larger than the cooking surface. Refer to manufacturer
specifi cations. An exhaust fan with a rating of 1,000 CFM (cubic
feet per minute) (472 liters per second) or more may be necessary
to effectively remove smoke and other cooking by-products from
the area under the hood. RHP Vent Hoods are available, contact
your local dealer.
THIS UNIT MUST NOT BE LOCATED IN A FULLY ENCLOSED
AREA OF ANY KIND.
ENSURE PROPER COMBUSTION AIR AND COOLING
AIRFLOW
Proper airfl ow (Fig. 10-1) MUST be maintained for the searing
station to perform as it was designed. If airflow is blocked,
overheating and poor combustion will result. Do not block the 1"
front air inlet along the bottom of the control panel or more than
75% of the cooking grid surface with pans or griddles.
GAS-SUPPLY PLUMBING REQUIREMENTS
For natural gas or a household propane system, rigid
1
/
2
" or
3
/
4
" black steel pipe or local code-approved pipe is required to
conduct the gas supply to the unit. Contact your local gas supplier.
Connect this pipe to a required C.S.A.-approved stainless-steel
fl ex connector (attached). An NPT adapter has been provided for
1
/
2
" pipe. DO NOT use a rubber hose within the unit enclosure.
Apply only joint compounds that are resistant to all gasses to all
male pipe fi ttings except fl are fi ttings. Make sure to tighten every
joint securely.
Note: If
1
/
2
" pipe is used with natural gas, it should be no
longer than 20'.
Important: A shut-off valve (not included) in the gas line
is required. It provides for safety when the unit
is not in use and for convenient maintenance and
repair. It must be installed within 6 feet of the unit.
Use a pipe joint compound resistant to all gasses
on all male fi ttings except fl are fi ttings.
GAS SUPPLY AND MANIFOLD PRESSURES:
For natural gas - normal 7" (17.78 cm) water column (w.c.),
minimum 5" (12.7 cm), maximum 10
1
/
2
" (26.7 cm). For propane
gas - normal 11" w.c., minimum 10" (25.4 cm), maximum 13" (33
cm).
INSTALLATION REQUIREMENTS (cont.)
REV 0 - 1601191040
L-C2-450
Fig. 10-1 Ventilation Diagram
OFF
HI
LIGHT
LO
W