CONNECT THE GAS SUPPLY
For propane cylinders:
For connecting a propane unit to a portable propane tank,
read the safety warnings and follow the instructions in the
section SAFE USE AND MAINTENANCE OF PROPANE
GAS CYLINDERS.
Note: When a propane cylinder is installed inside
of the enclosure, the guidelines found in the
ENCLOSURE REQUIREMENTS section
MUST be followed.
For household propane or natural gas units:
CAUTION: Use only C.S.A. listed stainless-steel fl ex
connectors within the enclosure.
WARNING
A rubber or plastic connector will rupture or leak,
resulting in an explosion or serious injury if used
inside the appliance enclosure.
1. Locate the attached fl ex connector (found underneath
the unit) and route it to the gas-supply stub.
2. Turn OFF the gas supply at the source. Remove
the
1
/2" adapter that is loosely connected to the fl ex
connector. Attach the adapter to the gas-supply stub
using a pipe joint compound that is resistant to all
gasses. Tighten securely. Then attach the open end
of the fl ex connector to the adapter. Tighten securely.
3. Turn the burner control knobs to the OFF position.
Turn the gas supply on. Then carefully check all gas
connections for leaks with a brush and half-soap/
half-water solution before lighting. NEVER USE A
MATCH OR OPEN FLAME TO TEST FOR LEAKS.
4. Close the dedicated gas-supply shut-off valve.
COUNTER PREPARATION
Consult Table 1 for non-combustible enclosure cut-out dimensions. An RHP insulating liner must be used if any
supporting construction is combustible. Consult the instructions that come with the liner for dimensions and
additional installation information before beginning the installation.
This searing station must be supported by the stainless-steel hanger extending from the upper portion of the
frame. The hanger rests on the left, right, and back of the countertop.
The control panel is designed to sit fl ush against the enclosure front wall (see Fig. 12-2). If the non-combustible
enclosure countertop extends beyond the front wall, creating a countertop overhang (see Fig. 12-1), it must be
cut fl ush with the front wall for the width of the control panel or a gap will be created exposing the forward portions
of the left and right side fi re walls of the unit. See the MODEL SPECIFICATIONS section.
Note: It is not necessary to remove the control panel or knobs to install this unit.
INSTALLATION
GAP CREATED
IDEAL
Flush-mounted
control panel
Proposed cut-
out in overhang
(Countertop) (Countertop)
Overhang
Control panel
stops here
Fig. 12-1 Fig. 12-2
REV 0 - 1412031145
L-C2-451
Fig. 12-3 Gas connection diagram
OFF
To gas
system
Dedicated manual
shut-off valve
Gas inlet pipe
Flex
connector
Hanger
Countertop
Cut-out
Pipe adapter