Installation Instructions

13
INSTALLATION (cont.)
CONNECT TO A POWER SOURCE
CAUTION: Improperly connected wires will cause damage to
the unit and may result in property damage and/
or personal injury.
The unit comes with a 6' wire extension to retrieve power from
a separately purchased Aurora grill. Select Aurora grills are
equipped with power supply boxes, which can supply power
to the searing station. Alternatively; an optional power supply
box may be ordered and installed to individually power this unit.
Contact your dealer for ordering information.
To install using the wire extension:
1. Locate the power supply box inside of the island enclosure
and disconnect the power cord (See Fig. 13-2, A).
2. Disconnect the grill wire harness extension connectors
from the power supply connectors. See Fig. 13-2, (B)
3. Locate the end of the searing station wire extension that
has two molex and ground connections. Connect the
extension (plug) molex connection to the power supply
(receptacle) molex connection and ground wires (See Fig.
13-3, C).
4. Connect the extension (receptacle) molex to the grill (plug)
molex connection and ground wires (See Fig. 13-3, D).
5. Connect the opposite end of the extension to the searing
station as shown in Fig. 13-3, E (molex and ground wire
connections).
6. Reconnect the power cord (see Fig. 13-3, F).
Proceed to the SLIDE UNIT INTO ENCLOSURE section.
To install using a power supply box (not included):
1. Install the power supply box at least 12 inches below the
bottom of the searing station.
2. Fasten the power supply box to the inside of the enclosure.
3. Connect the power supply box connectors to the searing
station wire harness extension, as shown in Fig. 13-4, A
(molex and ground wire connections).
4. Connect the searing station wire harness extension to
the searing station, as shown in Fig. 13-4, B (molex and
ground wire connections).
5. Plug the power cord into a properly wired and inspected GFCI
receptacle, 15 AMP minimum (not included). See Fig. 13-4,
C.
Note: Use a heavy duty grounded extension cord if
necessary.
Fig. 13-2 Disconnect grill connections
A
B
Power supply
box
Grill wire
harness
extension
Fig. 13-1 Connection detail
Receptacle
Plug
REV 0 - 1412031145
L-C2-451
Fig. 13-3 Connect searing station to grill setup
C
D
E
Double searing
station
Searing station
wire harness extension
Fig. 13-4 Connect searing station to power supply
A
B
Searing station
wire harness extension
Power supply
box
C
F
Double searing
station