Installation Guide

REV 0 - 1810251605
L-C2-583
9
OVERHEAD CONSTRUCTION (ROOF) [8ft]
VENT PIPING (TOP OR REAR)
Install 10" round galvanized (single wall) vent piping as required.
Installation will depend on roof / rear wall construction.
DUCT COVER (if applicable)
(To enclose transition and/or area above hood.
Some installs may not require a duct cover.)
S
P
A
C
E
R
N
O
N
C
O
M
B
U
S
T
I
B
L
E
R
E
A
R
W
A
L
L
HOOD
Transition
GAS
GRILL
Note: Drawings are not to scale.
Fire Magic offers a spacer and duct cover specifically designed for your vent hood. Reference the
information below for an overall orientation. (See Table 2 and contact your dealer for ordering information.)
In order to use these prefabricated components, ensure the component dimensions allow for an appropriate
install as addressed below (as individual setups may vary).
REFER TO INSTALLATION SECTION FOR COMPLETE DETAILS REGARDING ALL INFORMATION FOUND ON THIS PAGE.
INSTALLATION REQUIREMENTS - FIRE MAGIC SPACER & DUCT COVER
THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.
Installation must be done by a qualified professional service technician.
Below is a diagram of a generic installation.
Please review and understand this section prior to proceeding with installation.
Alternatively, a custom spacer and soffit can be constructed that are appropriate for your individual
setup. See the following page for details.
The Spacer depth is based upon 8" between a non-combustible wall
and the rear of the grill (i.e. 4" backsplash + 4" required clearance).
The Duct Cover height is based upon the transition height. It also is
based upon a 30-33" countertop-to-hood height, and an 8' high ceiling.
DUCT COVER
(if applicable)
SPACER
8"
30-33"
12"
20
1
/4"
Width varies
by model:
(36", 42", 48", 60")
18"
Width varies
by model:
(36", 42", 48", 60")
TOP OR REAR VENTING POSSIBLE,
TOP VENTING SHOWN
12"
18"